Polycom RMX 4000 Hardware Guide

DC Power Rail Module

A DC power rail module includes a power inlet, circuit breaker, EMI filter and backplane connectors. Power input to the system is fed via a power rail through backplane into the power supply. Each DC power rail has its own dedicated power cable. The circuit switch on the rear of the RMX activates independently any power rail installed on the RMX. An DC system has two DC rails, one for each power rail. On failure, a DC power rail is field replaceable and the RMX must be switched OFF from the two circuit switches and the mains.

Component Slot Allocation

On the RMX™ 4000, components have been assigned dedicated slots as

defined in Table 1-11. Slot numbers are located on both the front and rear of the RMX™ 4000.

Table 1-11RMX™ 4000 Slot Numbering

Slot ID/No.

Card/Component

Requirement

 

 

 

1-4

MPM+/MPMx

Mandatory: At least 1 MPM+/MPMxcard

 

Cards

is required. Each media card also

 

 

requires either an RTM ISDN or an RTM

 

 

LAN card.

 

 

 

5

Fabric Switch

Mandatory

 

Module (FSM

 

 

4000)

 

 

 

 

6

CPU 2

Not Available (NA)

 

 

 

7

Logo Panel

Not Available (NA)

 

 

 

8

CTNL 4000 unit

Mandatory

 

(CPU 1)

 

 

 

 

9-11

AC Power Supply

An RMX with AC power has 3 power

 

 

supplies installed. A 3rd power supply is

 

 

redundant (n+1).

 

 

Note: Not used with DC powered

 

 

systems. DC powered systems receive

 

 

Direct Current from the power rail .

 

 

 

1-31

Page 37
Image 37
Polycom DOC2559C manual DC Power Rail Module, Component Slot Allocation, Slot ID/No Card/Component Requirement