Chapter 2- Component Replacement

9Ensure that the metal ejector levers are fully retracted into their housings.

10Tighten the captive screws on the rear panel of the RMX 4000 that secure the RTM LAN card.

11Reconnect the cables.

12Turn ON the RMX 4000.

Replacing the Fabric Switch Module (FSM 4000)

1Ensure that the power switch/circuit switch on the RMX 4000 is turned OFF (O).

2Loosen the captive screws that fasten the module to the MCU.

3Remove the Fabric Switch Module (FSM 4000). Use the metal ejector levers to pull the Fabric Switch Module (FSM 4000) out of its slot in the backplane.

4Carefully slide the Fabric Switch Module (FSM 4000) out through the front panel.

5On the card to be installed, move the ejector levers to their fully open position.

6Slide in the replacement Fabric Switch Module (FSM 4000).

7Push the Fabric Switch Module (FSM 4000) firmly into the backplane, making sure it is properly seated in its slots.

2-18

Page 62
Image 62