Polycom VIEWSTATION EX outboundcallroute, numberofmonitors <1..4|get>, Description, Example

Models: VIEWSTATION EX

1 224
Download 224 pages 61.71 Kb
Page 120
Image 120
numberofmonitors

ViewStation EX, ViewStation FX, and VS4000 API Guide

numberofmonitors

numberofmonitors <{1..4}get>

numberofmonitors <{1..4}> numberofmonitors get

Description

This command sets the number of TV monitors that are connected to the system.

1..4

Sets the number of monitors allowed. Maximum number

 

is 4 for ViewStation FX and VS4000 systems, and 2 for

 

ViewStation EX systems.

get

Displays the current setting (1, 2, 3, or 4).

Example

numberofmonitors 2

User Interface Screen Location

System Info>Admin Setup>Video/Cameras>Monitors>TV Monitors: Number of Monitors

outboundcallroute

outboundcallroute <gatewayisdnget>

Description

This command sets the default outbound calling route.

gateway

Use gateway if your outbound call needs to be handled

 

by a gateway.

isdn

Use isdn if your system is connected to an ISDN line.

 

ISDN is the default.

get

Displays the current setting (gateway or isdn).

112

www.polycom.com

Page 120
Image 120