Primera Technology C-1000P manual LEx,y,hlen,vlen

Models: C-1000 C-1000P

1 66
Download 66 pages 28.14 Kb
Page 36
Image 36

(Table continued from previous page)

Command

Description

Parameter

 

 

 

 

Ip1,p2,001

Select symbol set**

p1:

7 or 8 data bits

 

 

p2:

symbol set

JB

Disable back feed**

 

 

JF

Enable back feed**

 

 

LEx,y,hlen,vlen

Line draw by

hlen: horizontal length

 

exclusive

vlen: vertical length

LOx,y,hlen,vlen

Line draw by OR

 

 

LWx,y,hlen,vlen

Draw white line

 

 

 

 

 

 

N

Clear frame buffer

 

 

O[,C][,N][,D]

Select options

 

 

Pp1[,p2]

Print label

p1:

label set number

 

 

p2:

copy number of

 

 

 

each label

PAp1[,p2]

Print automatic

 

 

 

 

 

 

Qp1,p2[,+p3]

Set label and

p1:

label length

 

gap length**

p2:

gap length

 

 

p3:

offset length

Qw

Set label width**

w:

label width

Rx,y

Set origin point**

 

 

 

 

 

 

Sp1

Set print speed

p1:

speed value, 2~4

 

 

 

 

U

Print configuration

 

 

UN

Disable Error Report

 

 

US

Enable Error Report

 

 

Vvn,dn,just,string

Define variable

vn:

variable index

 

 

dn:

digit number

 

 

just:

L,R,C and N

 

 

 

for field

 

 

 

justification

Xx,y,thick,ex,ey

Draw box

ex, ey: end position

 

 

 

thick: line

 

 

 

thickness

ZT

Set print direction

ZS:

print from top

ZB

 

ZB:

print from bottom

ZS

Enable/disable

power-on default is

ZN

store-to-Flash++

ZN(disabled)

?

Download variables

 

 

 

or counters

 

 

d1,hadj

Set horizontal posi-

hadj:

adjustment in

 

tion adjustment**

 

dots.

d2,hadj

Set horizontal

same as d1, except it is

 

position

no saved to E2PROM

 

adjustment

 

 

32 Command Language Quick Reference

Page 36
Image 36
Primera Technology C-1000P manual LEx,y,hlen,vlen