DEC LA120 Emulation

Overrides the “Emulation” value in the interface setup menu.

A numeric value for n may be specified in two different ways, with equivalent results: a single byte with a value of 00 to 07 hex, or a single printable ASCII character “0” to “7” (30 to 37 hex).

If more than one emulation has been selected, ESC ESC ? will return to the previously selected emulation. This is particularly useful when the previous emulation is unknown. Please beware that the memory (stack) is only one level deep.

ESC ESC @ will return to the default emulation, as specified by the “Emulation” value in the interface setup menu.

This chapter describes DEC LA120 emulation. If a different interface is selected, the control codes and escape sequences described in this chapter will no longer be applicable.

Example: The following escape sequences will select Printek emulation, load form one, and then return to the previous emulation.

Escape Sequence:

ESC

ESC

7

ESC

L

1

ESC

ESC

?

Hexadecimal:

1B

1B

07

1B

4C

01

1B

1B

3F

81

Page 87
Image 87
Printek 8000 manual DEC LA120 Emulation