Table B-9. Set Config Port Parameters (Continued)

B – Command Line Interface

0

 

 

Set Config Command

 

 

 

 

 

 

 

 

 

 

 

 

 

Table B-9. Set Config Port Parameters (Continued)

 

 

 

 

 

Parameter

Description

 

 

 

 

 

 

SymbolicPortName

Descriptive name for the port. The name can be up to

 

 

 

 

32 characters excluding #, semicolon (;), and comma

 

 

 

 

(,). The default is Port n where n is the port number.

 

 

ALFairness

Arbitration loop fairness. Enables (True) or disables

 

 

 

 

(False) the switch’s priority to arbitrate on the loop.

 

 

 

 

The default is False.

 

 

DeviceScanEnabled

Enables (True) or disables (False) the scanning of the

 

 

 

 

connected device for FC-4 descriptor information

 

 

 

 

during login. The default is True.

 

 

ForceOfflineRSCN

Enables (False) or disables (True) the immediate

 

 

 

 

transmission of RSCN messages when

 

 

 

 

communication between a port and a device is

 

 

 

 

interrupted. If enabled, the RSCN message is delayed

 

 

 

 

for 200 ms for locally attached devices and 400 ms for

 

 

 

 

devices connected through other switches. The

 

 

 

 

default is False. This parameter is ignored if

 

 

 

 

IOStreamGuard is enabled.

 

 

ARB_FF

Send ARB_FF (True) instead of IDLEs (False) on the

 

 

 

 

loop. The default is False.

 

 

InteropCredit

Interoperability credit. The number of buffer-to-buffer

 

 

 

 

credits per port. 0 means the default (12) is

 

 

 

 

unchanged. Changing interoperability credits is

 

 

 

 

necessary only for E_Ports that are connected to

 

 

 

 

non-FC-SW-2-compliant switches. Contact your

 

 

 

 

authorized maintenance provider for assistance in

 

 

 

 

using this feature.

 

 

ExtCredit

Extended credits. The number of port buffer credits

 

 

 

 

that this port can acquire from donor ports. The

 

 

 

 

default is 0.

 

 

FANEnable

Fabric address notification. Enables (True) or disables

 

 

 

 

(False) the communication of the FL_Port address,

 

 

 

 

port name, and node name to the logged-in NL_Port.

 

 

 

 

The default is True.

 

 

 

 

 

 