Fans

2 – General Description

0

 

 

Fans

 

 

 

 

 

 

 

 

2.6

Fans

The switch is equipped with two fans as shown in Figure 2-10. If one fan should fail, the other fan is capable of providing the necessary cooling until the failed fan can be replaced. The fans are hot swappable and interchangeable. Air flow can be front-to-back or back-to-front depending on the switch model. Refer to ”Fans” on page 6-4for information about removing fans, replacing the fans, and air flow direction.

Fans

Figure 2-10. Fans

2.7

Switch Management

The switch supports the following management tools:

„SANsurfer Switch Manager

„SANsurfer Switch Manager web applet

„SANsurfer Switch Manager Application Programming Interface (API)

„Command line interface (CLI)

„Simple Network Management Protocol (SNMP)

„File Transfer Protocol (FTP)

2.7.1

SANsurfer Switch Manager

SANsurfer Switch Manager is a workstation-based Java® application that provides a graphical user interface for fabric management. This includes SANsurfer Performance Viewer which graphs port performance. SANsurfer Switch Manager can run on a Windows, Solaris, or Linux workstation. A management workstation connects to the fabric through the Ethernet port of one or more switches and can provide in-band management for all other switches in the fabric. Refer to the SANbox2-8c/16 Switch Management User’s Guide for information about the SANsurfer Switch Manager application and its use.

2-10

59021-09 A

Page 36
Image 36