topology

B – Command Line Interface

0

 

 

Show Command

 

 

 

 

 

 

 

 

 

 

 

 

 

Table B-16. Switch Operational Parameters (Continued)

 

 

 

 

 

 

 

Parameter

Description

 

 

 

 

 

 

SwitchDiagnosticsStatus

Results of the power-on self test

 

 

SwitchTemperatureStatus

Switch temperature status: normal,

 

 

 

 

warning, failure

 

 

 

 

 

 

topology

Displays all connected devices.

users

Displays a list of logged-in users. This is equivalent to the User List command.

version

Displays an introductory set of information about operational attributes of the switch. This keyword is equivalent to the About keyword.

Examples The following is an example of the Show Chassis command:

SANbox2 #> show

chassis

 

Chassis Information

 

-------------------

 

BoardTemp (1)

- Degrees Celsius

32

BoardTemp (2)

- Degrees Celsius

36

FanStatus (1)

 

Good

FanStatus (2)

 

Good

PowerSupplyStatus (1)

Good

PowerSupplyStatus (2)

Good

HeartBeatCode

 

1

HeartBeatStatus

Normal

The following is an example of the Show Domains command:

SANbox2 #> show domains

 

Principal switch

is (remote): 10:00:00:60:69:50:0b:6c

Upstream Principal ISL is

: 1

Domain ID List:

 

 

Domain 97

(0x61)

WWN = 10:00:00:c0:dd:00:71:ed

Domain 98

(0x62)

WWN = 10:00:00:60:df:22:2e:0c

Domain 99

(0x63)

WWN = 10:00:00:c0:dd:00:72:45

Domain 100

(0x64)

WWN = 10:00:00:c0:dd:00:ba:68

Domain 101

(0x65)

WWN = 10:00:00:60:df:22:2e:06

Domain 102

(0x66)

WWN = 10:00:00:c0:dd:00:90:ef

Domain 103

(0x67)

WWN = 10:00:00:60:69:50:0b:6c

Domain 104

(0x68)

WWN = 10:00:00:c0:dd:00:b8:b7

B-62

59021-09 A

Page 164
Image 164
Q-Logic QLA2342, SB2A-16B manual Table B-16. Switch Operational Parameters Continued, topology, users, version