EDGE 60 Pellet Fireplace

F. Recommended Sequence of Installation

G. Items to Verify During Test Burn

NOTICE:

Read and understand Sections 6 through 10 for detailed information before installing the fi replace.

Follow all clearances as specifi ed.

The choice of fi nishing material and decorative front must be determined before installation can begin as it will determine the placement of the fi replace.

Outside air is required on all installations and the Outside Air Kit must be ordered separately.

Check for leaks in the exhaust venting system. Do you see any smoke?

Remember on a fi rst burn odors and vapors are released due to the curing of the high tem- perature paint. The focus is on the venting system.

Check overall operation, are there any error codes on the Wall Control?

Confi rm that outside air is hooked up and properly sealed. Is there cold air infi ltration?

 

Recommended Sequence

 

 

1.

Identify the exhaust vent and outside air locations

 

and install necessary venting components including

 

wall thimble, fi re stop or roof fl ashing for a verti-

 

cal termination. NOTE: Outside Air Kit must be

 

ordered separately.

 

 

2.

Complete the framing.

 

 

3.

Install the electrical junction box near the electrical

 

opening on the left side of the appliance. Maximum

 

distance of 9 inches (229mm) from appliance.

 

 

4.

Identify the location of the wall control and run the

 

wire (25 ft [7.62 meters] in length) to the left side of

 

the appliance.

 

 

5.

Prepare the fi replace for the exhaust vent adapter.

 

Install adapter, seal with high temp silicone and

 

screws and install all cover plates.

 

 

6.

Preset the nailing fl anges depending on the thick-

 

ness of your fi nishing material.

 

 

7.

Ensure that fi replace is level before securing in

 

place. If not level the decorative front will not swing

 

out properly.

 

 

8.

IT IS CRUCIAL FIREPLACE IS ROBUSTLY

 

SECURED. Slide the fi replace into place and

 

secure to the fl oor with the securing brackets and to

 

the wall. See page 33 for detailed instructions.

 

 

9.

Attach the exhaust and outside air venting to the

 

appliance.

 

 

10.

Hook up power and the wall control.

 

 

11.

Slide the fi replace out on the rail system to validate

 

that it is secure and there is no defl ection in the

 

outer can.

 

 

12.

Slide the fi replace back into the outer can. Re-attach

 

the bolts and brackets. Double check they are cor-

 

rectly positioned to ensure the exhaust gaskets are

 

properly sealed to prevent combustion leakage.

 

 

13.

A burn test must be performed before fi nishing

 

material is installed. (See Item “G”).

 

 

14.

Install the fi nishing material.

 

 

15.

Install the decorative front.

 

 

WARNING

Crush Hazard!

To avoid tipping over, this appliance must be securely fastened to the fl oor.

The fi replace must be secured in place as outlined in Section 6 and 7.

When servicing the fi replace, the fi replace slides foward on the rail system.

Tipping can occur if fi replace is not properly secured to the fl oor.