Quadra-Fire 7051-158B Soft Start Cycle SS-Low / SS-Med, Auto-Clean Cycle, Automatic Mode

Models: 7051-158B

1 58
Download 58 pages 35.93 Kb
Page 11
Image 11

R

EDGE 60 Pellet Fireplace

2.Soft Start Cycle (SS-Low / SS-Med)

Once the fi re is lit:

The appliance moves into the low soft-start cycle as it continues to build the fi re

More fuel will be added

As the fi re builds, the appliance will change to medium soft-start mode

The heating cycle begins

5.Auto-Clean Cycle

The fi repot auto-clean system will cycle:

When the appliance is fi rst plugged in

When the house reaches temperature and the appliance shuts down

At prescribed intervals, depending on the type of fuel se- lected

When starting up after an electrical interruption

3. Heating Cycle ( Auto / Man - L, ML, M, MH, H)

There are two choices in the Automatic / Manual menu of how your appliance will operate:

Automatic Mode

The wall control will turn the heat output level up or down depending on how far the room temperature is from the desired temperature

The digital display will read AUTO:M, i.e. automatic-me- dium level

As the room temperature approaches the desired tem- perature, the appliance will turn down to lower settings

When the home reaches your set temperature, the appli- ance will go into the shutdown cycle

Manual Mode

Set the heat output setting from the main screen

The right bottom button will read HEAT OUTPUT

You can operate the appliance from any of the 5 levels

On the lowest level (MAN: L) the appliance will stay on longer, burn less fuel per hour, and will take longer to bring the home up to your desired temperature

On the highest setting (MAN:H) the appliance will burn more fuel per hour, and bring your home up to tempera- ture more quickly

In Manual mode the heat output does not change but will stay at the setting you chose until the comfort level is reached (meaning the thermostat has been satisfi ed). Turn to OFF to stop operation.

4.Shutdown Cycle

Once your home has reached your set temperature:

Appliance will stop feeding fuel and allow the fi re to dimin- ish

Convection blower will continue to run until the appliance cools to appropriate temperature

Appliance will begin the auto-clean cycle

If your appliance is running and the auto-clean cycle is initi- ated, the appliance will revert to shutdown cycle.

The fl oor of the fi repot will open and dump the ash into the ash pan

It takes approximately 2 minutes to complete the auto- clean cycle

The fl oor will then shut, and if the thermostat is still call- ing for heat, the fi re will start again

During this auto-clean cycle, the convection blower may continue to run. The combustion blower will continue to run.

Additional Screen Messages:

READY It is telling you that the home is up to temperature and doesn’t need any heat.

-- - - - The screen will show 5 dashes when the wall control and the control board are NOT communicating with each other. Check that the wiring on the thermostat is prop- erly connected.

MAINTENANCE BURN This indicates the appliance is operating on battery backup, prior to the auto-clean. The maintenance burn will keep the system from shutting down as the appliance will not automatically re-light in battery back-up mode.

OFF The AUTO/MANUAL SETTING screen has been set to OFF. Set the appliance to OFF when performing periodic maintenance to prevent an unexpected startup.

BLANK SCREEN The ON/OFF switch may in OFF posi- tion. Turn to ON position.

CAUTION

Tested and approved for wood pellets, shelled fi eld corn, wheat and black oil sunfl ower seeds. Burning of any other type of fuel voids your warranty.

December 6, 2011

7051-158B

Page 11

Page 11
Image 11
Quadra-Fire 7051-158B Soft Start Cycle SS-Low / SS-Med, Auto-Clean Cycle, Heating Cycle Auto / Man L, ML, M, MH, H