Page 54 7051-158B December 6, 2011
R
EDGE 60 Pellet Fireplace

When describing the location of a component,

it is always AS YOU FACE THE FRONT OF

THE APPLIANCE.

B. Component Functions
1. Auto-Clean Motor
Location: Behind and under the fi repot on the left side, inside
the convection air chamber
Function: It automatically opens and closes the fi repot fl oor
so ashes can fall into the ash pan.
2. Auto-Clean Switch
Location: On top of the auto-clean motor
Function: Communicates to the control board when the fi repot
fl oor is open and when the auto-clean system has completed
its cycle and is back in the home (closed) position.
3.
12 Volt Battery Back-Up Cable (Optional Accessory)
Location: Plugs into the appliance at the lower left front of
the appliance.
Function: An icon will display on the wall control when the
appliance has lost main power and is running on battery
back-up.
4. Combustion (Exhaust) Blower
Location: Mounted in the bottom right rear of appliance.
Function: Pulls the exhaust from the appliance and pushs it
out through the venting system.
5. Control Board
Location: Lower left side of appliance.
Function: Controls the functioning of the appliance and
communicates with the wall control. The control board can
only be opened by an authorized dealer.
6. Convection Blower
Location: Mounted at the bottom left rear of the appliance
Function: Pushes heated air through the heat exchange
system into the room.
7. Door Switch
Location: Mounted on the right side of the fi rebox behind
the door handle
Function: Senses when the door is open and will display an
icon on the wall control and will turn off the auto-clean system
and feed motor for safety.
8. Feed System
Location: On the right side of the appliance and can be
removed as an entire assembly. The assembly includes
the feed motor, mounting bracket, bearing and feed spring
(auger).
Function: The hollow feed spring (auger) pulls pellets up the
feed tube from the hopper area and drops them down the
feed chute into the fi repot
9. Firepot
Location: Inside fi rebox and is made of high quality ductile
iron.
Function: The fl oor of the fi repot automatically opens for
cleaning and is operated by the auto-clean fi repot system.
The fl oor needs to return to a completely closed position or
the appliance will not operate properly.
10. Fuses
Location: One AC fuse and one DC fuse is located on the
inside of the control board and a third fuse is located in the
power supply. Figures 54.1 & 54.2 on page 54.
Function: The AC fuse operates the igniter and the DC
fuse operates all of the other components. The third fuse
protects the components in the power supply. A fuse will
blow should a short occur and shut off power to the appli-
ance. The fuses can only be replaced by an authorized
dealer.
11. Heat Exchanger
Location: Behind the baffl e. Remove the cast iron baffl e
to access the heat exchanger.
Function: Transfers heat from the exhaust system into the
convection air chamber.
12. Hopper Lid Switch
Location: Lower front right side of appliance on the power
switch cover.
Function: Senses whether the hopper lid is open and dis-
plays an icon on the wall control and will turn off the feed
motor.
13. Interlock Switch
Location: Lower front right side of appliance behind power
switch.
Function: Causes the auger to stop functioning and will be
opened when the appliances slides are extended.
14. Igniter (Heating Element)
Location: Mounted on the base of the fi repot.
Function: Combustion air travels over the red hot igniter
creating super heated air that ignites the pellets or other
fuels.
15. Power Receptacle
Location: Lower rear of the appliance
Function: Check the wall receptacle for 120 volt, 60 Hz
(standard current). Make sure the outlet is grounded and
has the correct polarity.