BLOWER CLEANING AND/OR REPLACEMENT
Cleaning is recommended at least once yearly or as needed.
1.Disconnect power and turn off gas supply.
2.Unplug blower at molex connector (see “A” below).
3.Remove two screws on back plate of blower compartment.
4.Slide blower compartment away from stove.
5.Vacuum or brush off dust and lint from fan blades.
For Replacement:
Follow instructions above for removal of blower.
1.Key two fingers on the blower compartment into slots on stove back.
2.Connect the molex connector. (See “A” in figure below)
3.Rotate the compartment up.
4.Insert and tighten the two screws.
5.Reconnect power and turn on gas supply.
“A”
Close up of
molex connection.
Note:
Take care not to lose the rubber on blower compartment fingers. If rubber is removed vibration can occur during blower operation.
Blower compartment fingers.
Page 42