SAFETY NOTICES, CONT.
WARNING
Do not operate appliance with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or the gas supplier.
SPECIFICATIONS
| NATURAL GAS | PROPANE |
Manifold pressure | 3.5” WC | 10.0” WC |
Minimum inlet gas supply pressure | 4.5” WC | 11 0” WC |
Maximum inlet gas supply pressure | 7.0” WC | 14.0” WC |
BTU input rating (high) | 40,000 BTUH | 40,000 BTUH |
BTU output rating (high)* | 34,000 BTUH | 34,000 BTUH |
BTU input rating (low) | 26,000 BTUH | 27,000 BTUH |
BTU output rating (low)* | 22,100 BTUH | 23,000 BTUH |
Steady State Efficiency* | 85% | 85% |
*Maximum vent, blower off |
|
|
LISTINGS
The
Page 5