Flame Troubleshooting, cont.
2.If vertically vented, a restrictor strap is required to reduce the volume of combustion air, which in turn will raise the flame height.
Restrictor Strap
FIG. B
NOTE: This plate rests on damper shaft.
3.If vented vertically with a horizontal run included; determine if the rise to run is close to the venting graft maximum, i.e. you are using the maximum horizontal for the amount of vertical. If the vertical rise is much greater than the horizontal run the restrictor strap may be installed to slow combustion air. If this method is used, light the stove for the first time and watch for flame lift (blue flame
Tall Stringy Flame
Single tall flame
1.If there is a single flame that is tall and stringy and the other flames look acceptable,
Many tall flames
1.If the appearances of the majority of the flames are tall and stringy, the entire burner needs more primary air. This can be accomplished by turning the shutter adjustment