DLT VS80 Tape Drive Installation and Operations Guide

Table 3-2.Understanding Errors Indicated by Front Panel LEDs (Continued)

Symptom

Problem

Solution

 

 

 

The host server or

The SCSI bus might be

If your tape drive is the last or only device

workstation does not

improperly terminated.

on the SCSI bus, make sure the tape drive is

recognize the tape drive.

 

properly terminated.

 

 

(continued...)

 

If the tape drive is not the last or only device

 

 

on the SCSI bus, check all of the SCSI cable

 

 

connections and make sure the last device

 

 

on each end of the SCSI bus is terminated

 

 

and powered on.

 

 

Note: The SCSI host bus adapter must usually

 

 

be terminated.

 

 

 

 

The SCSI terminator might

Make sure the terminators are placed only at

 

not be at the end of the SCSI

each end of the SCSI bus—one at the host bus

 

bus or more than two

adapter and one on the last device on the bus,

 

terminators might be present

for both the internal and tabletop tape drives.

 

on the SCSI bus.

 

 

 

 

 

The SCSI host bus adapter

Move the SCSI host bus adapter to a different

 

might be in a defective

expansion slot.

 

expansion slot.

 

 

 

 

 

The SCSI bus might be too

Make sure the total length of the SCSI bus does

 

long.

not exceed these ANSI SCSI standards:

 

 

19 feet (6 meters) for an SE bus

 

 

40 feet (12 meters) for an LVD SCSI bus

 

 

with multiple devices

 

 

82 feet (25 meters) for an LVD SCSI bus

 

 

with a single device

 

 

10 feet (3 meters) for a Fast SCSI-2 or Ultra

 

 

SCSI-1 bus.

 

 

 

There are fatal or non-fatal

The SCSI bus might be

If the tape drive is the last or only device on

errors for which you cannot

improperly terminated.

the SCSI bus, make sure the tape drive is

find the cause.

 

properly terminated. Make sure only the last

 

device is terminated.

 

 

 

 

If the tape drive is not the last or only device

 

 

on the SCSI bus, check all SCSI cable

 

 

connections and make sure the last device

 

 

on the SCSI bus is terminated and powered

 

 

on.

 

 

 

 

The AC power source may

Plug the tabletop tape drive’s power cable

 

not be properly grounded

into a power outlet on the same circuit as the

 

(tabletop tape drive only).

host server or workstation.

 

 

 

 

Plug the tabletop tape drive’s power cable

 

 

into a different power outlet.

 

 

 

001596-01 Rev A07

May 2004

3-21

Page 35
Image 35
Quantum DLT VS80 manual Understanding Errors Indicated by Front Panel LEDs