Quantum LTO-3 manual Mean Time Between Failures, Specification Description

Models: LTO-3

1 98
Download 98 pages 32.63 Kb
Page 60
Image 60

Chapter 5

Specifications

 

 

Mean Time Between Failures

 

 

 

 

 

Table 10

Reliability

 

Specification

Description

 

 

 

 

 

 

 

 

 

 

 

Non-recoverable error

Less than 1 in 1017 bits

 

 

 

rate

 

 

 

 

 

 

 

 

 

Error recovery and

• Error correction code techniques

 

 

 

control

(C1 and C2 ECC)

 

 

 

 

Read-after-write (RAW)

 

 

 

 

• Error monitoring and reporting (error log)

 

 

 

 

• Retry on

 

 

 

 

 

 

 

 

Mean time between

250,000 hours MTBF at 100% duty cycle:

 

 

 

failures (MTBF)

power applied and tape moving continuously

 

 

 

 

(Desktop drive; 50,000 hours at full load and

 

 

 

 

25°C)

 

 

 

 

 

 

 

 

Cartridge load/

300,000 cartridge load/unload cycles (no

 

 

 

unload

thread)

 

 

 

 

 

 

 

 

Mean time to replace

Less than 30 minutes

 

 

 

(MTTR)

 

 

 

 

 

 

Mean Time Between Failures

The mean time between failures (MTBF) for the internal drive is specified at 250,000 hours minimum. This specification includes all power-on and operational time but excludes maintenance periods. Operational time is assumed to be 100% of the power-on time. Operational time is the time the tape is loaded.

The MTBF for the desktop drive power supply is 50,000 hours with the unit operated at full load and 25°C.

Note: The MTBF rating does not represent any particular drive, but is derived from a large database of test samples. Actual rates may vary from unit to unit.