Chapter 2 Installation

Installing an Internal LTO-3 Tape Drive

Bus Composition Table 3 defines the connections that make up the ADT bus. With the exception of Sensea and Sensed this standard defines the behavior of these connections only when an initiator port asserts Sensea and the target port asserts Sensed.

Table 3 ADT Bus

Connections

Connection

 

Connection

 

 

Name

O/M

Type

Driven By

Connection Definition

 

 

 

 

 

Reseta

O

Signal

automation

An automation device may use this

 

 

 

port

connection to signal a reset request to a data

 

 

 

 

transfer device. A data transfer device shall

 

 

 

 

treat the receipt of a signal on this connection

 

 

 

 

as a port logout

 

 

 

 

 

Sensea

M

Sense

automation

A data transfer device shall use this

 

 

 

port

connection to sense the presence or absence of

 

 

 

 

an automation device on the ADT bus.

 

 

 

 

 

Senseaux

O

Sense

 

A vendor unique sense connection. This

 

 

 

 

standard does not define the use of this

 

 

 

 

connection.

 

 

 

 

 

Sensed

M

Sense

DTD port

An automation device shall use this

 

 

 

 

connection to sense the presence or absence of

 

 

 

 

a data transfer device on the ADT bus.

 

 

 

 

 

Signalaux

O

Signal

 

A vendor unique signal connection. This

 

 

 

 

standarddoes not define the use of this

 

 

 

 

connection.

 

 

 

 

 

Txa - Rxd

M

Tx-Rx

automation

An automation device shall use this

 

 

 

port

connection to send serialized data. A data

 

 

 

 

transfer device shall receive serialized data on

 

 

 

 

this connection.

 

 

 

 

 

Txd - Rxa

M

Tx-Rx

DTD port

A data transfer device shall use this

 

 

 

 

connection to send serialized data. An

 

 

 

 

automation device shall receive serialized

 

 

 

 

data on this connection.

 

 

 

 

 

LTO-3 Tape Drive User’s Guide