Appendix

1.3

ACTIVE PAR

Function

: Implements multi-boot function by activating one of the partitions.

Limitation : When no partition exists, this button is disabled.

Steps

: If there’re two or more partitions, choose one of them by pressing F5

 

 

key.

Note

 

: After setting active partition, a letter “A” will be shown in front of this

 

 

partition.

1.4

CREATE MIR

Function

: Adds mirror partition for the disk partition that has no mirror.

Limitation : This function should be performed by order, for example, from partition

 

 

1 to 4. If no disk space remains or the last partition has its mirror

 

 

partition already, this button is disabled.

Steps

: After pressing the “CREATE MIR” button, use F5 key to choose the

 

 

partition to create mirror. The partition of which the size is bigger than

 

 

the left disk space will be ignored.

1.5

DELETE MIR

Function

: Deletes the mirror partition.

Limitation : If there is no mirror partition, this button is disabled. This function

 

 

should be performed in reverse order, for example, from partition 4 to 1.

Steps

: After pressing the “DELETE MIR” button, only the final mirror partition

 

 

can be deleted in order to keep the continuous disk space. If the

 

 

warning message is confirmed, the mirror partition will be deleted. By

 

 

pressing “N” or “ESC” key, the system quits.

1.6

UNINST SFW

Function

: Uninstall RecoveryEasy.

Limitation : None.

Steps

: After pressing the “UNINST SFW” button and the warning message is

 

 

confirmed, RecoveryEasy will be uninstalled. By answering “N”, the

 

 

system quits.

Note

 

: After RecoveryEasy is uninstalled, all the mirror areas have been

 

 

disconnected with the relate partitions. If no partition is deleted or

 

 

changed in size, or no other partition is created, users have chance to

 

 

“Recover existing RecoveryEasy settings” when next time entering

 

 

RecoveryEasy partition interface, meanwhile the password will be set

 

 

as default setting “qdiqdi”.

1.7

OTHERS

F12

: Switches to Recovery User Interface.

ESC

: Exits from the Partition User Interface. If users made some mistakes, for

 

example, wrongly delete a partition, do not press the “ESC” key, press the

 

reset button on your system at once, in this way users can save their system.

Manual for PlatiniX 2 series