Appendix E Parameters and Screens IPmux-1/1E Installation and Operation Manual
E-14 IPmux-1 E1/T1 Configuration
To overwrite the system and reconfigure it according to default settings:
Type Y.
IPmux-1 is reconfigured according to default settings. Following this,
IPmux-1 performs an automatic Reset.
OR
Type N to exit and return to the General Configuration menu.
1. Setting default parameters from an ASCII terminal erases all the configurations
and optionally asks if you want to erase Host IP and Default Gateway
Configuration.
2. Setting default parameters from Telnet or NMS does not erase the Host IP or
Default Gateway Configuration.
E.4 IPmux-1 E1/T1 Configuration

E1 Configuration

E1 CONFIGURATION
1. Channel Status Enable
2. Transmit Clock Source Adaptive
3. Loopback State Disable
4. Rx. Sensitivity -10dB
5. Line Type CRC4 enable
6. Idle Code 7E
7. Signaling Mode CAS enable
8. Cond. Data pattern FF
9. Cond. CAS (ABCD)pattern 01
ESC. Exit
Select item from the menu.
Use <Esc> key or keys <1> to <9>
Figure E-19. E1 Physical Layer Configuration Menu
When “unframed” mode is selected, the Idle Code, Signaling Mode, Cond Data
Pattern and Cond CAS Pattern fields are not present.
When CAS Disabled is selected, the Cond CAS Pattern field is not present.
Note
Main Menu
2. Configuration
2. E1/T1
Configuration
Note