Chapter 2 Installation IPmux-1/1E Installation and Operation Manual
2-2 Installation and Setup
The DC power source must be isolated from the mains supply by double or
reinforced insulation. A suitable fuse or a circuit breaker should be integrated in
the negative power-supply line.
Allow at least 90 cm (36 inches) of frontal clearance for operator access. Allow at
least 10 cm (4 inches) clearance at the rear of the unit for cable connections. Make
sure that the ventilation holes are not blocked.
The ambient operating temperature of IPmux-1/1E is 0o to 50o C (32o F to 122o F),
at a relative humidity of up to 90%, non-condensing.
2.3 Package Contents
The IPmux-1/1E package contains the following items:
IPmux-1/1E unit
Power cord
Kit containing hardware for mounting the unit in a 19-in rack (optionally
supplied)
RM-25 for IPmux- 1
RM-27 for IPmux- 1E.

Power Cable

IPmux-1/1E comes equipped with the power cord connected to the AC/DC
interface on the rear panel.
2.4 Equipment Needed
IPmux-1/1E needs no special tools for installation. A screwdriver is necessary when
mounting IPmux-1/1E in a 19-in rack.
2.5 Installation and Setup

Setting Jumpers

IPmux-1

In general, IPmux-1 internal jumpers and switches do not need to be configured
by the user. Therefore, removing the product cover is not required.
Caution