Chapter 5 Application Configuration Procedures IPmux-1/1E Installation and Operation Manual
5-6 IPmux-1
E1/T1 Configuration
To configure E1/T1:
1. From the Main menu, select 2 Configuration.
2. From the Configuration menu select 2 E1/T1 Configuration (see Figure 5-3).
3. Select Transmit Clock and choose Adaptive.
4. Select Line Type and choose CRC4 Disable.
5. Select Signaling Mode and choose CAS Disable.
6. Press <S> to save the configuration.
7. Press <Esc> a number of times to return to the Configuration screen.
Remember to press <Enter> after modifying each parameter. Press <S> to save
all changes on the menu.
E1/T1 CONFIGURATION
1. Channel Status Enable
2. Transmit Clock Source Adaptive
3. Loopback State Disable
4. Rx. Sensitivity -10dB
5. Line Type CRC4 Disable
6. Idle Code 7E
7. Signaling Mode CAS Disable
8. Cond. Data pattern FF
9. Cond. Cas <ABCD> pattern 01
ESC. Exit
Select item from the menu.
Figure 5-3. E1/T1 Configuration Menu
DS0 Bundle Configuration
To create the bundles:
1. From the Configuration menu select 5 DS0 Bundle Configuration (see
Figure 5-4).
2. Select Time slot number and enter 1 – 10.
3. Select Time slot Current Status and choose Set.
4. Press <S> to Save.
5. Press <Esc> to return to the Configuration screen.
Main Menu
2. Configuration
2. E1/T1
Configuration
Main Menu
2. Configuration
5. DS0 Bundle
Configuration
Note
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com