Appendix E Parameters and ScreensIPmux-1/1EInstallation and Operation Manual

 

 

Table E-21. E1/T1 Statistics Parameters

 

 

 

Alarm

Failure

Comments

 

 

 

LOS

Loss of Signal

Sync LED Off

 

 

For T1: A second during which 192 contiguous pulse positions have no

 

 

pulse of either positive or negative polarity (signal is more than 30 dB

 

 

below nominal amplitude.

 

 

For E1: A second during which 255 contiguous pulse positions have no

 

 

pulse of either positive or negative polarity.

 

 

 

LOF

Loss of Frame

Sync LED Off

 

 

For E1/T1: A second during which an OOF (see below) error persists for

 

 

2.5 seconds and no AIS error (see below) is detected.

 

 

 

LCV

Line Code

Line Code Violation

 

Violation

For T1: A second during which BPV (Bipolar Violation) or EXZ errors have

 

 

 

 

occurred.

 

 

For E1: A second during which two consecutive BPVs of the same polarity

 

 

are received.

 

 

BPV is the occurrence of a pulse with the same polarity as the previous

 

 

pulse.

 

 

EXZ is the occurrence of a zero string greater than 15 for AMI or 7 for B8ZS.

 

 

Complies with ITU-TI.431, 0.161, G.775 and G.821 standards.

 

 

 

Rcv RAI

Remote

Sync LED flashes

(Yellow

Alarm

For E1/T1, a second during which tan RAI pattern is received from the far

Alarm)

Indication

end when the far-end framer enters a RED state (Loss of Frame).

 

 

 

 

 

AIS

Alarm

Sync LED is Off

 

Indication

For T1: A second during which an unframed “all 1” signal is received for

 

Signal–

 

3 milliseconds.

 

Received

 

 

 

from User

For E1: A second during which a string of 512 bits contains fewer than

 

 

three zero (0) bits.

 

 

 

FEBE

Far End Block

Number of seconds in which the FEBE indication is received from the

 

Error

remote E1 device.

 

 

For E1 MF-CRC4 only

BES

Bursty Errored

 

Seconds

 

(Errored

 

Second type

 

B)

Number of seconds with from two to 319 CRC error events with no AIS nor SEF (Framing Bit Errors) error detection

Complies with AT&T TR-62411 and TR-54016 standards. Not applicable if Line Type is set to Unframed

T1-ESF or E1-CRC4 modes

E-30 Performance Monitoring

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Page 128
Image 128
RAD Data comm IPmux-1E operation manual Table E-21. E1/T1 Statistics Parameters, Alarm Failure Comments

IPmux-1E, IPmux-1 specifications

RAD Data Comm is a renowned manufacturer known for its high-quality communication solutions, and among its notable offerings are the IPmux-1 and IPmux-1E devices. These compact and versatile products are designed for efficient network integration and data transport over various mediums including IP-based networks.

The IPmux-1 is a powerful multiplexer that enables the transmission of multiple channels of voice, data, and even fax over a single IP link. It supports various protocols such as E1, T1, and V.35, making it an ideal solution for businesses looking to optimize their existing infrastructure while upgrading to more modern technologies. The device is also equipped with advanced features such as payload compression and error correction, which ensure high-quality performance even over less reliable networks.

On the other hand, the IPmux-1E is an enhanced version of the original device, featuring additional capabilities that extend its flexibility and functionality. This model supports a higher density of channels and offers advanced management and monitoring tools that provide users with detailed insights into network performance. The IPmux-1E is particularly beneficial for service providers and enterprises that require a more robust solution capable of handling greater bandwidth and multiple service types across a single platform.

Both IPmux models utilize advanced packet-processing technology, facilitating seamless data encapsulation and reducing latency, which is critical in today’s fast-paced digital environment. They are designed to easily integrate with existing infrastructure, allowing organizations to transition smoothly to a more modern telecommunications framework without the need for significant investment in new hardware.

Key characteristics of the IPmux-1 and IPmux-1E include their reliability, low power consumption, and rugged design suitable for deployment in various locations. Their modular architecture offers users the flexibility to scale their systems according to evolving needs.

In summary, RAD Data Comm's IPmux-1 and IPmux-1E devices provide an excellent solution for organizations seeking to consolidate their voice and data services into a single network infrastructure. With their advanced features, support for various protocols, and robust performance, they are well-suited for both enterprise and service provider applications, ensuring efficient communication and data management in today's increasingly connected world.