IPmux-1/1E Installation and Operation Manual Chapter 1 Introduction
Technical Specifications 1-27
Signal Levels
Jitter Performance
Receive: 0 to –10 dB
Transmit: ±2.7V ± 10%, adjustable, measured in range
0 to 133 feet, without CSU
AT&T TR-62411, G.824 standards
Indicators General:
PWR ON when power supply is OK
OFF when a malfunction is detected
RDY ON when self-test is successfully completed
OFF during self-test
BLINKS when self-test fails
Ethernet Port:
LINK OFF when line is not acti ve
ON when line is OK
ACT OFF when no activity
ON when a frame is being transmitted or
received on the line
100M OFF when 10 MHz
ON when 100 MHz
FDX OFF when half duplex
ON when full duplex
E1/T1 Port:
SYNC ON when the port is synchronized (no alarm)
OFF when signal loss, LOF or AIS is detected
(local alarm)
BLINKS when RDI is detected (remote alarm)
ISDN Port:
SYNC ON when the ISDN BRI frame is
synchronized (no alarm)
OFF when signal loss, LOF is detected
FXS Port:
SYNC ON when off-hook
OFF when on-hook
BLINKS when ringing
Note: All LEDs are green and ON after power-up.
Power
1 power supply
100 to 240 VAC, 50 or 60 Hz
–36 to –72 VDC (–48 VDC nominal)
Note: IPmux-1E only has AC power supply option.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com