IPmux-1/1EInstallation and Operation ManualAppendix E Parameters and Screens

Table E-17. Signaling Profile Configuration (Cont.)

Parameter

Possible Values

Remarks

 

 

 

Tx B

B, B Inverse, 0, 1

Specifies which ABCD Signaling Bit carries the on hook/off hook

 

 

information to the far-end device. One or more can be configured to

 

 

carry the off-hook/on-hook information, while the other bits should

 

 

be set to ‘1’ or ‘0’.

 

 

 

Tx C

C, C Inverse, 0, 1

Specifies which ABCD Signaling Bit carries the on hook/off hook

 

 

information to the far-end device. One or more can be configured to

 

 

carry the off-hook/on-hook information, while the other bits should

 

 

be set to ‘1’ or ‘0’.

 

 

 

Tx D

D, D Inverse, 0, 1

Specifies which ABCD Signaling Bit carries the on hook/off hook

 

 

information to the far-end device. One or more can be configured to

 

 

carry the off-hook/on-hook information, while the other bits should

 

 

be set to ‘1’ or ‘0’.

 

 

 

Note For example, if Rx = A, then all other Rx must be NC. If Rx = A Inverse, then all other Rx must be NC. Tx can be A, B , 0, 1.

Main Menu

2.Configuration

3.Bundle Connection Configuration

VLAN ID and VLAN Priority are configurable only if VLAN Tagging is set to Yes.

E.7 Bundle Connection Configuration

 

BUNDLE CONNECTION CONFIGURATION

1.

Bundle ID

1

2.

IP TOS

1

3.

TDM Bytes in Frame

48

4.

Connection Status

Disable

5.

Destination IP Address

0.0.0.0

6.

Next Hop

0.0.0.0

7.

Destination Bundle

1

8.

Jitter Buffer (x10 sec) rounded up 1000 sec steps! 300

9.

VLAN Tagging

YES

A. VLAN Id

EE

B. VLAN Priority

00

ESC. Exit

 

Select item from the menu.

Figure E-26. Bundle Connection Configuration