SPECIFICATIONS AND DIMENSIONS

ATMOSPHERIC UNITS

B

C

INDOOR

DRAFTHOOD

38"

13-1/4"

GAS

CONNECTION

A

J

4-3/8"

8-7/8"

(6-5/8" ASME)

(3-3/8" ASME)

 

32-11/16"40"

ELECTRICAL

STACKLESS

CONNECTION

OUTDOOR TOP

26-5/8"

(28-5/8" ASME)

28"

 

 

 

 

 

 

 

 

Shipping Weights (lbs)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard

ASME

 

 

BTUH

(A)

(B)

(C)

(J)

 

 

Heater

Heater

Indoor

Heater

Input

Cabinet

Flue

Indoor

Min.

Gas

Water

w/Stackless

w/Stackless

Draft-

Model

(000)

Width

Dia.

Drafthood

 

Conn.

Conn.

Top

Top

hood

R206A

199.5

20”

6”

61-5/8”

11-3/4”

3/4”

2”

187

206

12

 

 

 

 

 

 

 

 

 

 

 

R266A

266.0

23”

7”

62”

11”

3/4”

2”

210

229

15

 

 

 

 

 

 

 

 

 

 

 

R336A

332.5

26”

8”

63”

10-5/8”

3/4”

2”

230

249

17

 

 

 

 

 

 

 

 

 

 

 

R406A

399.0

29”

9”

64-9/16”

12-1/8”

3/4”

2”

249

268

20

 

 

 

 

 

 

 

 

 

 

 

Designation for a Digital heater using propane gas is “EP”; a Digital heater using natural gas is “EN”. Designation for a Millivolt heater using propane gas is “MP”; a Millivolt heater using natural gas is “MN”. Prefix “C” is for cast iron (ASME) headers; “P” is for plastic (polymer) headers.

Suffix “X” is for cupro-nickel tubing; “C” is for copper tubing.

EXAMPLE: P-R406A-EN-X= Plastic headers, 406 model size, digital, natural gas, cupro-nickel. Reduce input 4% for each 1000 ft above sea level when installed above 2000 ft elevation.

For Canada, no de-rating is required for elevations up to 4500 ft Plastic (polymer) headers cannot be used for ASME installations.

16

Page 16
Image 16
Raypak 406A, 206A, 407A, 337A, 336A, 207A, 267A, 266A operating instructions Specifications and Dimensions, Atmospheric Units