SPECIFICATIONS AND DIMENSIONS

Low NOx UNITS

B

C

INDOOR

DRAFTHOOD

31-13/16"

J

26-1/2"

ELECTRICAL

CONNECTION

20-1/2"

4-3/8"

8-7/8"

(6-5/8" ASME)

(3-3/8" ASME)

 

 

34"

 

STACKLESS

 

OUTDOOR TOP

7-3/4"

GAS

CONNECTION

A

(22-1/2" ASME)

28"

 

 

 

 

 

 

 

 

Shipping Weights (lbs)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard

ASME

 

 

BTUH

(A)

(B)

(C)

(J)

 

 

Heater

Heater

Indoor

Heater

Input

Cabinet

Flue

Indoor

Min.

Gas

Water

w/Stackless

w/Stackless

Draft-

Model

(000)

Width

Dia.

Drafthood

 

Conn.

Conn.

Top

Top

hood

R207A

199.5

20”

6”

55-5/8”

11-3/4”

3/4”

2”

174

193

12

 

 

 

 

 

 

 

 

 

 

 

R267A

266.0

23”

7”

56”

11”

3/4”

2”

197

216

15

 

 

 

 

 

 

 

 

 

 

 

R337A

332.5

26”

8”

57”

10-5/8”

3/4”

2”

219

238

17

 

 

 

 

 

 

 

 

 

 

 

R407A

399.0

29”

9”

58-1/2”

12-1/8”

3/4”

2”

237

256

20

 

 

 

 

 

 

 

 

 

 

 

Designation for a Digital heater using natural gas is “EN”.

Prefix “C” is for cast iron (ASME) headers; “P” is for plastic (polymer) headers. Suffix “X” is for cupro-nickel tubing; “C” is for copper tubing.

EXAMPLE: P-R407A-EN-X= Plastic headers, 407 model size, digital, natural gas, cupro-nickel. For altitudes above 5,000 ft., consult the factory.

For Canada, no de-rating is required for elevations up to 4500 ft. Plastic (polymer) headers cannot be used for ASME installations.