Raypak 337A, 406A Diagnostics, Reading A Fault, Status Codes, Program Modes, Display, Definition

Models: 266A 267A 207A 336A 337A 407A 206A 406A

1 55
Download 55 pages 6.49 Kb
Page 35
Image 35

NOTE: The LCD temperature display may not agree with the temperature reading of your pool or spa ther- mometer. The heater reads the water temperature at the inlet. Due to the circulation characteristics of any pool or spa, the water temperature at the inlet to the heater may differ from that observed at a given location in the pool or spa.

DIAGNOSTICS

 

READING A FAULT

The digital thermostat models are equipped with on- board diagnostic controls. If there is a safety fault, a fault code will be displayed along with a service indication.

If the PRS fault code is displayed, it indicates that there is insufficient water flow through the heater. Make sure the pool filter and pump strainer are clean before calling a service representative.

The word “SERVICE” will flash on and off if the PC board detects a known fault. The fault will be dis- played in three big letters on the lower left of the dis- play.

3 Letter

 

Service Will

 

Flash

Fault Code

 

 

 

See table

 

for fault

 

definition

Fig.# 9485

Fig.# 9482

STATUS CODES

 

PROGRAM MODES

Display

Definition

 

Display

Definition

CFH

Call for heat

CCC

Celsius setting

CLK

Time clock

F/C

Change from Fahrenheit to Celsius

EOL

End of line test (Factory Use Only)

FFF

Fahrenheit setting

LON

Low NOx Unit

RES

Reset defaults

LOW

Caution-low water temperature

SET

Set point max adjustment

OFF

Off mode

 

 

PRO

Propane gas configured

 

 

REM

Remote control activated

 

 

SPK

Spark

 

 

SPR

Spare fault code indicator

 

 

 

 

 

FAULT CODES

 

 

 

Display

Definition

 

 

BD1

Board failure

 

 

EEP

Microprocessor error

 

 

FAN

Blower pressure failure

 

 

FFL

Flame sensing when pilot and gas

 

 

 

valves are closed

 

 

GVC

Gas valve closed

 

 

GVO

Gas valve open

 

 

HL1

High limit switch #1 open

 

 

HL2

High limit switch #2 open

 

 

IGN

Ignition failure

 

 

ILO

Ignition lockout

 

 

PLT

Pilot failure

 

 

PRS

Water pressure switch open

 

 

ROL

Heat roll-out safety switch open

 

 

SNS

Sensor failure

 

 

VNT

Vent switch open

 

 