INSTALLATION

INSTALLATION

AERATION

ADJUSTMENT

Aeration Adjustment should only be per- formed by an authorized Regency® Installer at the time of installation or service.

The rear burner aeration is factory set but may need adjusting due to either the local gas supply or altitude.

The rear burner air shutter can be adjusted by moving the air shutter wire. Open (pull) the air shutter wire for a blue fl ame or close (push) for a more yellow fl ame.

*The front burner aeration is factory set, do not adjust this setting.

Minimum Air Shutter Opening:

NG

Front Burner*

1/8"

 

Rear Burner

1/4"

LP

Front Burner*

3/8"

 

Rear Burner

5/16"

CAUTION: Carbon will be produced if air shutter is closed too much.

STANDARD

FLUSH DOOR

NOTE: Install Finishing Trim prior to installing the Flush Door and Louvers.

1)The standard fl ush door comes with a black frame. To install the frame, simply hook the top door fl ange onto the top of the unit and swing the door towards the unit, diagram 1.

FLUSH LOUVERS

NOTE: Install Finishing Trim prior to installing the Flush Door and Louvers.

1)Install the top louver by sliding the two bracket clips into the brackets located underneath the top of the fi rebox.

2)Install the bottom louver by securing the louver onto the 2 hinges provided.

Note: Top and Bottom Louvers are different.

Note: Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty.

Rear Burner

Adjustment Wire

Diagram 1

2)Be careful that the glass gasket does not roll up; there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit. Diagram 2.

3) Installing the Manual Control Box

a)Ensure that the bottom louver is open.

b)Pull out the Manual Control Box from the right side under the bottom of the fi rebox.

c)Using the 2 screws on the louver, secure the control box onto the right side of the louver.

Adjustment Wire - Pull to open or

push to close aeration cap.

Diagram 2

3)Use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket. Repeat for 2nd spring. See diagram 3.

Manual Control Box

Diagram 3

NOTE: Springs and chain must always be OVER not under the gas line.

4)To remove the fl ush door, reverse the above steps.

32

Regency® P40 Direct Vent Gas Fireplace

Page 32
Image 32
Regency P40 Aeration Adjustment, Standard Flush Door, Flush Louvers, Minimum Air Shutter Opening Front Burner Rear Burner

P40, P40-LP, P40-NG specifications

The Regency P40 series, comprising the P40-LP, P40, and P40-NG models, represents a significant advancement in the world of portable radio communications. Designed with both versatility and performance in mind, these devices cater to a diverse range of users, from public safety professionals to outdoor enthusiasts.

One of the standout features of the P40 series is its robust build quality. The radios are engineered to withstand harsh environments, boasting IP67 water and dust resistance ratings. This ensures reliable performance even in challenging conditions, making them ideal for emergency responders who operate in adverse weather or rugged terrains. The P40's durable design is complemented by a lightweight construction, allowing for prolonged use without fatigue.

The P40 series is equipped with advanced digital technology that enhances both audio clarity and range. With a powerful speaker and noise-canceling capabilities, users can communicate clearly even in noisy surroundings. The P40-NG model takes this a step further by incorporating digital signal processing (DSP) technology, which optimizes sound for both transmission and reception.

Battery life is a critical aspect of any portable device, and the P40 series excels in this regard. With options for high-capacity lithium-ion batteries, users can expect extended operational times, vital for those on long shifts or field operations. Additionally, the smart battery management system provides real-time battery status updates, ensuring users are never caught off guard.

Interoperability is another key characteristic of the P40 series. The radios support multiple frequency bands and can seamlessly integrate with existing communication infrastructures. This capability is particularly beneficial for agencies that require coordination across various channels and networks.

User-friendly interfaces define the P40 series, with intuitive controls and customizable features. The color display on the P40 and P40-NG models enhances usability, allowing for easy navigation through settings and features. Furthermore, programmable buttons facilitate quick access to frequently used functions, ensuring efficient communication even in high-pressure scenarios.

Overall, the Regency P40-LP, P40, and P40-NG radios embody reliability, advanced technology, and ruggedness, making them essential tools for effective communication in a variety of demanding environments. With their combination of durability, audio performance, and battery life, these radios stand out as a top choice for both professional and recreational use.