Regency P40-NG, P40-LP Venting Arrangements, Installation, Allowable Vertical Terminations

Models: P40 P40-LP P40-NG

1 48
Download 48 pages 12.68 Kb
Page 20
Image 20
ALLOWABLE VERTICAL TERMINATIONS

INSTALLATION

VENTING ARRANGEMENTS

ALLOWABLE VERTICAL TERMINATIONS

INSTALLATION

The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90o elbows, with Rigid Pipe Venting Systems for Propane and Natural Gas. Two 45o elbows equal to one 90o elbow. Maximum of four 45o elbows allowed.

0

40

38

2

4

6

8

10

12

14

Vent must be supported at offsets.

Firestops are required at each floor level and whenever passing through a wall.

Maintainclearancestocombustiblesaslisted in the "Clearances" section.

Referto"VentRestrictorPosition"sectionfor details on how to change the vent restrictor to Set 1 or Set 2 if required.

Note: Mustuseoptionalflueadapterwhenusing Rigid Pipe (Part # 770-994).

 

36

 

34

 

32

 

30

 

28

 

26

 

24

(Feet)

22

20

Height

 

Vertical

18

 

16

14

12

10

8

6

4

2

0

Vent Restrictor on Set 2

Vent Restrictor on Set 1

Minimum 8’9” (2.6m)

Maximum: 40 ft. (12.2m)

Vent Restrictor

Factory Set

Maximum: 28 ft. (8.5m)

Minimum 12” (305mm)

Max. 10’ (3m)(centerline to centerline)

20

Regency® P40 Direct Vent Gas Fireplace

Page 20
Image 20
Regency P40-NG Venting Arrangements, Installation, Allowable Vertical Terminations, Vent must be supported at offsets