INSTALLATION
CLEARANCES
The clearances listed below are minimum distances unless otherwise stated:
A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions.
Caution Requirements
The top, back and sides of the fi replace are defi ned by standoffs. The metal ends of the standoff may NOT be
recessed into combustible construction.
Clearance to Combustibles from:
Back | 0" | (0mm) |
Side | 0" | (0mm) |
Floor | 0"* | (0mm) |
*Note: A hearth is required, unless the unit is raised
4" (102mm), see "Hearth Requirements" section for details.
Minimum Clearance from Top of Louver Opening:
Mantel Height min. 12" (305mm) (at 1" mantel depth)
Ceiling 39" (990mm)
Side Wall to Unit:
8" (203mm)
Horizontal Vent Clearances to Combustibles:
Top
Side
Bottom
Vertical Vent Clearances to Combustibles:
All Sides
Alcove Clearances:
Max. Depth | 36" | (914mm) |
Min. Width | 56" | (1422mm) |
Min. Height | 72" | (1829mm) |
WARNING
Fire hazard is an extreme risk
if these clearances (air space) to combustible materials are not adhered to. It is of greatest importance that this fireplace and vent system be installed only in accordance with these instructions.
INSTALLATION
Regency® P40 Direct Vent Gas Fireplace | 9 |