Regency P40-NG Clearances, Installation, Clearance to Combustibles from, Side Wall to Unit, Back

Models: P40 P40-LP P40-NG

1 48
Download 48 pages 12.68 Kb
Page 9
Image 9
CLEARANCES

INSTALLATION

CLEARANCES

The clearances listed below are minimum distances unless otherwise stated:

A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions.

Caution Requirements

The top, back and sides of the fi replace are defi ned by standoffs. The metal ends of the standoff may NOT be

recessed into combustible construction.

Clearance to Combustibles from:

Back

0"

(0mm)

Side

0"

(0mm)

Floor

0"*

(0mm)

*Note: A hearth is required, unless the unit is raised

4" (102mm), see "Hearth Requirements" section for details.

Minimum Clearance from Top of Louver Opening:

Mantel Height min. 12" (305mm) (at 1" mantel depth)

Ceiling 39" (990mm)

Side Wall to Unit:

8" (203mm)

Horizontal Vent Clearances to Combustibles:

Top 2-1/2" (64mm)

Side 1-1/2" (38mm)

Bottom 1-1/2" (38mm)

Vertical Vent Clearances to Combustibles:

All Sides 1-1/4" (32mm)

Alcove Clearances:

Max. Depth

36"

(914mm)

Min. Width

56"

(1422mm)

Min. Height

72"

(1829mm)

WARNING

Fire hazard is an extreme risk

if these clearances (air space) to combustible materials are not adhered to. It is of greatest importance that this fireplace and vent system be installed only in accordance with these instructions.

INSTALLATION

Regency® P40 Direct Vent Gas Fireplace

9

Page 9
Image 9
Regency P40-NG Clearances, Installation, Clearance to Combustibles from, Minimum Clearance from Top of Louver Opening