MAINTENANCE
POWER MODULE
REPLACEMENT
1)Unplug the power source.
2)Remove the Power Module by lifting it up off of the velcro and pull out.
CONTROL MODULE
REPLACEMENT
1)Unplug the power source.
2)Remove the Power Module by lifting it up off of the velcro and pull out.
6)Replace the Control Module and reverse steps to
BACKUP BATTERY
REPLACEMENT
(within Power Module)
Power Module | Power Module | |
3) Remove the Power Module cover by | 3) Remove the Control Module by lifting it up | |
removing the 2 screws, one on each side | ||
off of the velcro and pull out. | ||
of the box. | ||
|
Control Module
4) Remove the Heat Shield from the Control
4) Unplug all wires connected to the Power Module by removing the 2 screws. Module (J1, J2 & J3 on the power module
circuit board).
J3
J2
Heat Shield
J1
5) Unplug all wire harnesses and manual control box cable plugged into the Control module.
5)Pull Power Module off of pins and replace.
NOTE: The 9V battery operates the rear burner and the AA battery operates the DC Sparker for lighting the pilot under power outage conditions.
1)Unplug the power source.
2)Remove the Power Module by lifting it up off of the velcro and pull out.
Power Module
3)Remove the Power Module cover by removing the 2 screws, one on each side of the box.
4)Replace the 9V and AA battery and reverse steps to
MAINTENANCE
6)Reverse steps to
Regency® P40 Direct Vent Gas Fireplace | 41 |