INSTALLATION

IMPORTANT MESSAGE

SAVE THESE

INSTRUCTIONS

The P40 Direct Vent Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fi replace is installed in compliance with manufacturers instructions and all applicable codes.

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE.

CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPE- CIALLY THE FIREPLACE GLASS, AND SHOULD STAYAWAYTOAVOID BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

CLOTHING OR OTHER FLAMMABLE MATERIALSHOULDNOTBEPLACED ON OR NEAR THE APPLIANCE.

GENERAL SAFETY

INFORMATION

1)The appliance installation must conform with local codes or, in the absence of local codes, with the current Canadian or National Gas Codes, CAN1-B149 or ANSI Z223.1 Installation Codes.

2)The appliance when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code.

3)See general construction and assembly instructions. The appliance and vent should be enclosed.

4)This appliance must be connected to the specifi ed vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fi tted as per Venting instructions.

5)Inspect the venting system annually for blockage and any signs of deterioration.

6)Venting terminals shall not be recessed into a wall or siding.

7)Any safety glass removed for servicing must be replaced prior to operating the appliance.

8)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fi replace.

9)Wearglovesandsafetyglassesforprotection while doing required maintenance.

10)Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination.

11)Under no circumstances should this appliance be modifi ed. Parts that have to be removed for servicing should be replaced prior to operating this appliance.

12)Installation and any repairs to this appliance should be done by an authorized service person.Aprofessionalservicepersonshould be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.

13)Do not slam shut or strike the glass door.

14)Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.

15)The appliance area must be kept clear and free of combustible materials, (gases and other fl ammable vapours and liquids).

Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

INSTALLATION

CHECKLIST

1)Locate appliance

a)Room location (Refer to "Locating Your Gas fi replace" section)

b)Clearances to Combustibles (Refer to "Clearances" section)

c)Mantle Clearances (Refer to "Mantel Clearances" section)

d)Framing & Finishing Requirements (Refer to "Framing & Finishing" section)

e)Venting Requirements (Refer to "Venting" section)

2)Assemble Top Standoffs and Top Facing Support and Side Nailing Strips (Refer to "UnitAssembly Prior to Installation). NOTE: Must be done before installing unit into place.

3)Install vent (Refer to "Venting Arrangement" sections).

4)Back-up battery installation. Refer to "Back- up Battery Installation" section.

5)Make gas and electrical connections. Test the pilot. Must be as per diagram (Refer to "Pilot Adjustment " section).

Convert to propane if desired (Refer to "Conversion from NG to LP" section).

6)Test Gas Pressure. (Refer to "Gas Pipe Pressure Testing" section).

INSTALLATION

Regency® P40 Direct Vent Gas Fireplace

7

Page 7
Image 7
Regency P40-LP Installation, Important Message Save These Instructions, Before YOU Start, General Safety Information

P40, P40-LP, P40-NG specifications

The Regency P40 series, comprising the P40-LP, P40, and P40-NG models, represents a significant advancement in the world of portable radio communications. Designed with both versatility and performance in mind, these devices cater to a diverse range of users, from public safety professionals to outdoor enthusiasts.

One of the standout features of the P40 series is its robust build quality. The radios are engineered to withstand harsh environments, boasting IP67 water and dust resistance ratings. This ensures reliable performance even in challenging conditions, making them ideal for emergency responders who operate in adverse weather or rugged terrains. The P40's durable design is complemented by a lightweight construction, allowing for prolonged use without fatigue.

The P40 series is equipped with advanced digital technology that enhances both audio clarity and range. With a powerful speaker and noise-canceling capabilities, users can communicate clearly even in noisy surroundings. The P40-NG model takes this a step further by incorporating digital signal processing (DSP) technology, which optimizes sound for both transmission and reception.

Battery life is a critical aspect of any portable device, and the P40 series excels in this regard. With options for high-capacity lithium-ion batteries, users can expect extended operational times, vital for those on long shifts or field operations. Additionally, the smart battery management system provides real-time battery status updates, ensuring users are never caught off guard.

Interoperability is another key characteristic of the P40 series. The radios support multiple frequency bands and can seamlessly integrate with existing communication infrastructures. This capability is particularly beneficial for agencies that require coordination across various channels and networks.

User-friendly interfaces define the P40 series, with intuitive controls and customizable features. The color display on the P40 and P40-NG models enhances usability, allowing for easy navigation through settings and features. Furthermore, programmable buttons facilitate quick access to frequently used functions, ensuring efficient communication even in high-pressure scenarios.

Overall, the Regency P40-LP, P40, and P40-NG radios embody reliability, advanced technology, and ruggedness, making them essential tools for effective communication in a variety of demanding environments. With their combination of durability, audio performance, and battery life, these radios stand out as a top choice for both professional and recreational use.