Regency P40-LP Vertical Venting with Two 2 90o Elbows, Vertical Venting with Three 3 90o Elbows

Models: P40 P40-LP P40-NG

1 48
Download 48 pages 12.68 Kb
Page 19
Image 19
Vertical Venting with Two (2) 90o Elbows

INSTALLATION

Vertical Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

Option V

H

V + V1

A)0' Min. 2' Max. 1' Min.

B)1' Min. 4' Max. 2' Min.

C)2' Min. 5' Max. 3' Min.

D)3' Min. 6' Max. 4' Min.

E)4' Min. 7' Max. 5' Min.

F)5' Min. 8' Max. 6' Min.

With these options, max. total pipe length is 30 feet with min. of 6 feet total vertical and max. 8 feet total horizontal.

Please note min. 1 foot between 90o elbows is required.

V1

VENT RESTRICTOR SETTING:

When total vertical exceeds total horizontal by 2x the vent restrictor setting is set to 1.

For additional vertical venting with 2 x 90o elbows, refer to next page.

H V

INSTALLATION

Vertical Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

V1

H1

H

V

 

 

Option

V H + H1 V + V1

A)0' Min. 2' Max. 3' Min.

B)1' Min. 2' Max. 3' Min.

C)2' Min. 3' Max. 4' Min.

D)3' Min. 4' Max. 6' Min.

E)4' Min. 5' Max. 7' Min.

F)5' Min. 6' Max. 8' Min.

G)6' Min. 7' Max. 9' Min.

H)7' Min. 8' Max. 10' Min.

With these options, max. total pipe length is 30 feet with min. of 10 feet total vertical and max. 8 feet total horizontal.

Please note min. 1 foot between 90o elbows is required.

VENT RESTRICTOR SETTING:

When total vertical exceeds total horizontal by 3x the vent restrictor setting is set to 1.

Regency® P40 Direct Vent Gas Fireplace

19

Page 19
Image 19
Regency P40-LP, P40-NG installation manual Vertical Venting with Two 2 90o Elbows, Vertical Venting with Three 3 90o Elbows