![GAS PIPE PRESSURE](/images/new-backgrounds/52266/5226649x1.webp)
INSTALLATION
GAS PIPE PRESSURE
TESTING
The appliance must be isolated from the gas supply piping system by closing its individual manual
Themanifoldpressureiscontrolledbyaregulator built into the gas control, and should be checked at the pressure test point.
Note: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve.
1)Make sure the valve is in the "OFF" position.
2)Loosen the "IN" and/or "OUT" pressure tap(s), turning counterclockwise with a 1/8" wide fl at screwdriver.
3)Attach manometer to "IN" and/or "OUT" pressure tap(s) using a 5/16" ID hose.
4)Light the pilot and turn the valve to "ON" position.
5)The pressure check should be carried out with the unit burning and the setting should be within the limits specifi ed on the safety label.
6)When fi nished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" fl at screwdriver. Note: Screw should be snug, but do not over tighten.
SIT VALVE DESCRIPTION
1)Gas on/off knob
2)Electronically Operated Hi/Lo
3)Pilot Adjustment
4)Thermocouple Connection - option
5)Outlet Pressure Tap
6)Inlet Pressure Tap
7)Pilot Outlet
8)Main Gas Outlet
9)Alternative TC Connection Point
BACK-UP BATTERY
INSTALLATION
(within Power Module)
The 9V battery operates the rear burner and theAAbatteryoperates theDC Sparker for lighting the pilot under power outage conditions.
1)Unplug the power source.
2)Remove the Power Module by lifting it up off of the velcro and pull out.
Power Module
3)Remove the Power Module cover by removing the 2 screws, one on each side of the box.
INSTALLATION
4)Install the 9V and AA battery.
Regency® P40 Direct Vent Gas Fireplace | 25 |