Regency P42-3 Zero Clearance Direct Vent Gas Fireplace

Vertical

Termination

24"

D

E

V

B

V

M

.

Inside corner detail

G

V

A

C

 

V

Fixed

 

 

Closed

F

V

Openable

 

 

B

B

V

B

Vertical

Termination

24"

18"

V

 

 

 

 

 

 

 

 

H

 

 

B

V

 

 

 

 

 

Openable

Fixed Closed

 

 

 

 

 

B

N

 

 

 

 

V

K

A

 

 

 

 

 

j

 

 

 

 

 

A

 

 

 

V

L

A

EXTERIOR VENT TERMINATION

V

Vent terminal

A

Air supply outlet

 

Area where terminal is not permited

 

 

 

 

 

 

 

A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm)

H= Not to be installed above a meter/regulator assembly within (3'/90cm) horizontally from

B= Clearance to window or door that may be opened *(12"/30cm)

 

the centerline of the regulator.

C= Clearance to permanently closed window *(min. 12"/30cm)

J=

Clearance to service regulator vent outlet *(min 36"/90cm)

D= Vertical clearance to ventilated soffit located above the terminal within a horizontal

K= Clearance to non-mechanical air supply inlet to building or the combustion air inlet to

 

distance of (24"/60cm) from the centerline of the terminal (min. 18"/46cm) check with

 

any other appliance *(12"/30cm)

 

local code.

L=

Clearance to a mechanical air supply inlet *(min. 72"/1.8m)

E=

Clearance to unventilated soffit (min. 15"/38cm)

M= Clearance above paved sidewalk or a paved driveway located on public property

F=

Clearance to outside corner: with AstroCap Termination Cap (min 6"/15cm), with Dura-

 

*(min. 84"/2.1m)

 

Vent Termination Cap (13"/33cm)

N= Clearance under veranda, porch, deck, or balcony *(min. 12"/30cm)

G= Clearance to inside corner: with AstroCap Termination Cap (min 6"/15cm), with Dura-

Vent Termination Cap (12"/30cm)

Note:

-A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

-Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.

-If the vent termination is accessible, a certified guard shall be installed.

* As specified in CGA B149 Installation Code. Note: Local codes or regulations may require different clearances.

9

REQUIREMENTS

INSTALLATION

Page 9
Image 9
Regency P42-LP3, P42-NG3 installation manual Exterior Vent Termination