Regency P42-LP3 Vertical Termination With CO-LINEAR Flex System, Required Parts, Description

Models: P42-LP3 P42-NG3

1 44
Download 44 pages 17.93 Kb
Page 17
Image 17

INSTALLATION

VERTICAL TERMINATION

WITH CO-LINEAR FLEX SYSTEM

THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE.

Masonry chimneys may take various contours which the flexible liner will accommodate. However, keep the flexible liner as straight as possible, avoid unnecessary bending.

The Air Intake pipe must be attached to the inlet air collar of the termination cap.

This appliance is designed to be attached to two 3" (76mm) co-linear aluminium flex running the full length of the chimney. See the Venting Arrangements on next page for minimum and maximum heights.

Required Parts:

Part # Description

946-529 Co-linear DV Vertical Termination Cap

948-305 3" Flex - 35 ft.

946-563 Co-Axial to Co-Linear Adapter Kit which contains the following: Co-linear Flex Adapter

Outer Pipe

Inner Pipe Adapter 510-994 Rigid Pipe Adaptor

Alternate Approved Caps

980Vertical Termination Cap

991High Wind Cap

923GK 3" Co-linear Adapter with flashing

FPI Cabinet and/or Flat Wall Mantles may be used in these applications ensuring that clearances to com- bustibles are maintained.

Co-linear DV

Vertical Termination

Cap # 946-529

A maximum of two certified

joiner kits may be used

per length. #948-305 (35 ft)

Exhaust

Flue

Outer

Pipe

with Kit# 946-563

Pipe Length

Liner

Air Intake

Co-Linear

Flex

Rigid Pipe Adaptor

 

 

# 510-994

90 Degree

 

 

Elbow

Inner Pipe

 

 

 

 

Adapter

 

 

with Kit#

 

 

946-563

Adapter with Kit# 946-563

Regency P42-3 Zero Clearance Direct Vent Gas Fireplace

17

Page 17
Image 17
Regency P42-LP3 Vertical Termination With CO-LINEAR Flex System, Required Parts, Description, Alternate Approved Caps