OPERATING INSTRUCTIONS
OPTIONAL | OPTIONAL | OPERATING |
REMOTE CONTROL | WALL THERMOSTAT | INSTRUCTIONS |
Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty.
The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.
1)Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very im- portant). Run wires from the fireplace to that location. Use Thermostat Wire Table.
2)Connect the two wires to the gas valve. See diagram below.
CAUTION
Do not wire millivolt remote control wires to 120V wire.
3)Install 3 AAA alkaline batteries in transmitter and 4 AA alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation.
OPTIONAL
WALL SWITCH
1)Run the supplied 15' of wire through the right or left side gas inlet opening. Be careful not to damage wire.
Note: We recommend a maximum of 15' of wire but if you wish to go with a longer run, use the Thermostat Wire Table.
2)Connect the wire to the supplied wall switch and install into the receptacle box.
CAUTION
Do not wire millivolt
wall switch wire
to 120V wire.
A wall thermostat may be installed if desired, connect the wires as per the wiring diagram. Use table below to determine the maximum wire length.
Note: Preferable if the thermostat is in- stalled on an interior wall.
Regency offers an optional programmable ther- mostat but any
CAUTION
Do not wire millivolt wall thermostat wires to 120V wire.
Thermostat Wire Table
Recommended Maximum Lead Length
Thermostat
Wire Size | Max. Length |
|
14 GA. | 50 Ft. |
|
16 GA. | 32 Ft. |
|
18 GA. | 20 Ft. |
|
20 GA. | 12 Ft. |
|
22 GA. | 9 Ft. |
|
|
|
|
1)Read and understand these instructions before operating this appliance.
2)Check to see that all wiring is correct and enclosed to prevent possible shock.
3)Check to ensure there are no gas leaks.
4)Make sure the glass in the door frame is properly positioned. Never operate the ap- pliance with the glass removed or with broken glass.
5)Verify that the venting and cap are unob- structed.
6)Ensure that the brick panels are installed.
7)Verify log placement. If the pilot cannot be seen when lighting the unit, the logs have been incorrectly positioned.
8)The unit should never be turned off, and on again without a minimum of a 60 second wait.
LIGHTING
PROCEDURE
IMPORTANT
To ignite or reignite the pilot,
you must first release the
tension springs below the door.
Only when the pilot holds, without pressure being applied to the control knob, reapply the tension springs to the door. The unit must not be operated with the tension springs unattached.
IMPORTANT: Gas cock knob cannot be turned from "PILOT" to "OFF" unless it is partially depressed.
1)Turn burner OFF using "ON/OFF" switch.