MAINTENANCE

REMOVING THE FAN

REPLACING THE FAN

REMOVING VALVE

1)Shut the power off.

2)Remove the bottom louver.

3)Remove terminal block cover and discon- nect the fan wires.

4)Disconnect white fan wire from the terminal block.

5)Disconnect black fan wire from the thermo- disc.

6)Disconnect fan ground wire.

7)Lift the fan off the two mounting studs and pull out.

IMPORTANT:

These fans collect a lot of dust from within your home. Ensure you main- tain these fan motors on a regular basisbyvacuumingoutthefansquir- rel cages.

1)Shut the power off.

2)Remove the bottom louver. Slide the fan in and push it towards the rear of the unit and slip it over the two mounting studs.

3)Remove the terminal block cover. Wire the fan to the terminal block as shown in the wiring diagram below.

4)Connect white wire from fan to neutral of terminal block.

5)Connect black wire from fan to the thermo- disc.

6)Connect fan ground wire. Refer to wiring diagram.

7)Attach the ground wire to the stove (ground lug provided).

8)Attach the terminal block cover.

Note: A 120 Volt AC power cord should be installed at rough-in stage so that the power is available. A three wire power cord can be used.

The bearings are lubricated for life. Do not lubricate them. Make sure you vacuum the fan area on a regular basis.

1)Shut off the gas supply.

2)Remove the louvers (and bay door if it is on).

3)Disconnect the inlet gas line.

Note: Be sure to have an 11/16" wrench on the tee to ensure that the whole line is not twisted

4)

Disconnect the 2 TP wires and the 2 TH

 

wires from the valve.

5)

Remove the Piezo igniter wire.

6)

Open and remove the flush door.

7)

Remove the logs.

8)

Remove the burner tube by removing the 3

 

Phillips head screws and then lift the burner

 

out.

9)

Remove the burner grate assembly by re-

 

moving the 3 Phillips head screws on the

 

feet of the grate assembly.

10) Brush away all the vermiculite and embers

 

from the right hand half of the fireplace.

11) Remove the top and right hand side brick

 

panels.

12) Remove the 12 Phillips head screws secur-

 

ing the valve access plate in place and then

 

lift the entire assembly out.

13) Undo the pilot tube from the valve with a

 

7/16" wrench.

14) Undo the quick drop out thermocouple nut

 

on the valve with a 9mm wrench.

15) Undo the "gas out" flare nut with a 13/16"

 

wrench.

16) Undo the "gas out" 90o elbow flare fitting

Grounding lug detail

with an 11/16" wrench.

17) Remove the 4 Phillips head screws from the

sides of the valve bracket and remove

valve.

Hint: If you are using black pipe, ensure

that there is a union by the valve, otherwise

removal will be almost impossible.

Regency P42-3 Zero Clearance Direct Vent Gas Fireplace