INSTALLATION

AERATION

BRICK PANELS

ADJUSTMENT

The aeration adjustment gears are located on the valve mounting plate and are accessed from underneath through the bottom louver opening.

To access the air shutter loosen the lock nut and then use the allen key to turn the turning gear which will adjust the air shutter. Open the air shutter for a blue flame or close it for a yellower flame. Tighten the lock nut when adjustment is complete. The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude.

CAUTION: Carbon will be produced if air shutter is closed too much. (Should be 3/16"(4mm) open for natural gas and 1/2" (13mm) for propane.)

Note: Aeration Adjustment should only be performed by an authorized Regency Installer at the time of installation or service.

1)Unhook the 2 spring loaded hooks from the bottom of the flush door and lift the Flush Front off the unit.

2)Unwrap the brick pattern panels from the protective wrapping.

Note: The logs must not be in the unit.

3)Insert the back brick panel first by carefully slipping it between the back wall of the firebox and the rear log bracket.

4)Put the side panels in next. Tilt them in towards the middle of the firebox and put the bottom front corner in first. Be very careful not to scratch them on the firebox hardware. Place them flat up against the wall, they should fit snugly against the top of the firebox.

5)Next is for the brick panel for the top of the firebox. With both hands, lift it up with the widest part towards you and the brick pattern facing down.

Slip the wide part up and into the top front of the firebox and then tilt the back side up over the back brick and push back until the back of the brick panel rests on top of the back panel. Slide the 2 top brick clips over the top brick panel and into the slots at the top of the firebox. See diagram below.

IMPORTANT: Dangerous operating conditions may occur if the panels are broken.