DV STOVE HORIZONTAL VENT KIT (# 946-116 & #946-216)

INSTALLATION

DV STOVE HORIZONTAL VENT KIT (# 946-116 & #946-216)

DV Stove Horizontal Vent Kit (2 ft. Part # 946-116 or 4 ft. Part # 946-216) includes all the parts needed to install the U39 with minimum horizontal and vertical vent dimensions. For installations that require longer vertical and/or horizontal vents

see the "Dura-vent Termiantion Kit and Component" sections.

Qty. Description

1) 1Rigid Pipe Section (Kit # 946-116: 2 ft. (1.2m) length,

Kit # 946-216: 4 ft. (1.2m) length), 6-1/2" (165mm) inside diameter

2)1Flex Liner, compressed aluminium 2 ply liner,

4" (102mm) inside diameter

3) 4spring spacers

4) 190 deg. Elbow

5) 1Adjustable pipe section 13-1/2" to 24" (343mm x 610mm), 2 pieces

6)1Thimble Cover

7)

1Wall Thimble (2 pcs.)

8)

1Adapter

9)

1AstroCap Termination Cap

10)

2Trim Collar

11)1tube of Mill-Pac, high temperature sealant

12) 12Screws, #8 x 1/2" Self tapping, Stainless Steel

13) 13Screws, #8 x 1/2" Self tapping, Black

14)4Screws #8 x 1-1/2" Drill Point, Black

15)4Screws #8 x 1-1/2" Drill Point, Stainless Steel

16) 8Wood screws #8 x 1"

Optional:

946-206 Vinyl Siding Standoff for AstroCap

Note:

a)Liner sections should be continuous without any joints or seams.

b)This is an approved system, therefore components in this system must not be substituted for any other manufacturer's

products.

DV STOVE HORIZONTAL VENT KIT INSTALLATION

Review the following sequence of instructions which are typical of most installations. The sequence may vary dependingonwallthickness.Referto vent location and clearance dimensions in "Exterior Vent Termination Locations" to "DV Stove Horizontal Vent Kit" sections.

1)Set the unit in its desired location. Check to determine if wall studs will be in the way of the venting system, adjust location until all clearances are met and there are no obstructions.

Note: A 1-1/2"(38mm) clearance around the outer pipe must be maintained except that only a 1" (25mm) clearance is needed at the termination end.

IMPORTANT:

Do not locate termination hood where excessive snow or ice buildup may occur. Be sure to check vent termination area after snow falls,

Minimum Installation Height: U39: 59-3/4" ( 1518mm)

and clear to prevent accidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.

2)Assemble a trial fit to determine the vertical center-line for the vent termination.

a)Cut a 9-1/2" x 9-1/2" (241mm x 241 mm) square hole on both the interior and exterior wall.

b)Install wall thimbles on both interior and exterior wall with 4 wood screws (#8 x 1") per thimble.

c)Attach the 2 piece adjustable pipe section to the vent terminal and slide into position from the exterior.

The larger diameter end of the adjustable pipe goes to the vent terminal.

d)Install the 90o elbow onto the adjustable pipe to determine the vertical centerline of the starter collar on the unit.

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove