Regency U39-NG1, U39-LP1 Installation, ONLY REQUIRED FOR THE U38, Burner Orifi ce

Models: U39-LP1 U39-NG1

1 44
Download 44 pages 36.34 Kb
Page 25
Image 25
Fig.5

INSTALLATION

WARNING!

Do not over tighten the screw. Recommended to grip the wrench by the short side.

14)Verify that if the conversion is from NG to LPG, the screw must be re- assembled with the red o-ring visible (Fig. 5).

17)Unscrew the pilot orifi ce with the allen key and replace with the LPG pilot orifi ce in the kit.

2)Remove the front control panel by unscrewing the 6 screws.

Red o-ring visible

Fig.5

LPG Configuration

18)Remove burner orifi ce with a 1/2" wrench while using a 9/16" wrench to hold onto the elbow behind the orifi ce, then discard the orifi ce.

3)Unplug the Piezo Ignitor wire and remove Piezo Ignitor from the control panel.

15)Re-assemble the black protection cap (Fig. 6).

Fig. 6

WARNING!

Also check that the pilot

and main burner injectors are appropriate for the gas type.

16)Pull off the pilot cap to expose the pilot orifi ce.

Burner Orifi ce

19)Reinstall new burner orifi ce LPG stamped #50 and tighten.

20)Reverse steps 3) to 2).

21)Attach the label "This unit has been converted to LPG" near or on top of the Serial # decal.

22)Replace yellow "NG" label with red "LPG" label.

ONLY REQUIRED FOR THE U38

Installation of the DC Sparker:

1)Remove the back pedestal cover by unscrewing the 4 screws.

4)Plug up the Piezo Ignitor mounting hole with the plastic plug.

5)Connect the DC spark generator wires to the SIT Valve with the screw, which is provided in the kit.

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove

25

Page 25
Image 25
Regency U39-NG1, U39-LP1 installation manual Installation, ONLY REQUIRED FOR THE U38, Burner Orifi ce