INSTALLATION
WARNING!
Do not over tighten the screw. Recommended to grip the wrench by the short side.
14)Verify that if the conversion is from NG to LPG, the screw must be re- assembled with the red
17)Unscrew the pilot orifi ce with the allen key and replace with the LPG pilot orifi ce in the kit.
2)Remove the front control panel by unscrewing the 6 screws.
Red
Fig.5
LPG Configuration
18)Remove burner orifi ce with a 1/2" wrench while using a 9/16" wrench to hold onto the elbow behind the orifi ce, then discard the orifi ce.
3)Unplug the Piezo Ignitor wire and remove Piezo Ignitor from the control panel.
15)
Fig. 6
WARNING!
Also check that the pilot
and main burner injectors are appropriate for the gas type.
16)Pull off the pilot cap to expose the pilot orifi ce.
Burner Orifi ce
19)Reinstall new burner orifi ce LPG stamped #50 and tighten.
20)Reverse steps 3) to 2).
21)Attach the label "This unit has been converted to LPG" near or on top of the Serial # decal.
22)Replace yellow "NG" label with red "LPG" label.
ONLY REQUIRED FOR THE U38
Installation of the DC Sparker:
1)Remove the back pedestal cover by unscrewing the 4 screws.
4)Plug up the Piezo Ignitor mounting hole with the plastic plug.
5)Connect the DC spark generator wires to the SIT Valve with the screw, which is provided in the kit.
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove | 25 |