Horizontal Venting with Two (2) 90o Elbows

INSTALLATION

Horizontal Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

 

V

H + H1

A)

3'

Min.

2' Max.

B)

5'

Min.

3' Max.

C)

8'

Min.

4' Max.

With these options, maximum total pipe length is 30 feet with minimum of 8 feet total vertical and maximum 4 feet total horizontal.

Please note minimum 1 foot between 90o elbows is required.

Lengths do not include elbow indicated

Vent restrictor position A (fully open), Refer to the "Venting Ar- rangement" section.

Vertical Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

Option V

H

V1 V + V1

A)1' Min. 1' Max. 1' Min. 2' Min.

B)1' Min. 2' Max. 2' Min. 3' Min.

C)2' Min. 3' Max. 2' Min. 4' Min.

D)2' Min. 4' Max. 2' Min. 4' Min.

With these options, max. total pipe length is 30 feet with min. of 4 feet total vertical and max. 4 feet total horizontal.

Please note min. 1 foot between 90o elbows is required.

Lengths do not include elbow indicated

Vent restrictor position A (fully open). Refer to the "Venting Arrangement" section.