MAINTENANCE

7)Tighten side panels nuts using the following procedure:

a.tighten top & bottom outside corner nuts

(2)

b.tighten inside nuts (3)

c.tighten top & bottom inside corners (2)

8)Tighten the 10 nuts on center glass retainer.

9)Repeat step 7 for other side panel.

10)Replace new gasket by gluing it in place.

11)Install door onto stove and check the seal.

FAN MAINTENANCE

Ifyourfanrequiresmaintenanceorreplacement, access to the fan is through the plate on the rear wall of the fi rebox. NOTE: the unit MUST NOT be operated without the fan access panel securely in place and correctly sealed.

IMPORTANT: These fans collect a lot of dust from within your home. Ensure you maintain these fan motors on a regular basis by vacuuming out the fan squirrel cages, around the motor, and around the grills on the back of the stove.

IMPORTANT

Disconnect power supply

before servicing

WARNING:

Electrical Grounding

Instructions

This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.

To Remove U39 Fan:

1)Unplug or disconnect power source to stove.

2)Remove all logs and the rear log support, then remove the 10 screws holding the access panel in place.

3)Unclip the black and white wires from the fan motor.

4)Open both side doors and gently pull the

ex pipe away from the center, otherwise the fan can catch on the fl ex pipe during installation and tear the pipe. Do not tear or damage the fl ex pipe.

Alternate Fan Access:

If the rear access cover is accessible,itcanberemovedto provide access to the fan.

5)Lift fan off of the 2 pins, tip back and pull through fi rebox opening. Disconnect the green ground wire from the right side of the fan as soon as you can reach it.

Replacing U39 Fan:

Reverse the above steps (1 - 5). If necessary install a new gasket before replacing the fan access panel. Make sure the fan wires and the ground wire are reattached.

Hint for pushing fan down onto pins - rub a bit of dish soap on the grommet so it will slide more easily onto the pin. Check to make sure the fan is seated properly on the pins - try to move the fan back and forth, there should be no noise, if there is check that the grommets haven't come loose.

DC SPARKER BATTERY

REPLACEMENT

The battery in the DC Spark box needs to be replaced annually.

1)Remove the DC Spark box from the back of the pedestal cover by removing the heat shield.

2)Remove the Heat Shield from the DC Spark Box.

3)Place 1 AA battery into the DC Spark Box by opening the battery compartment.

4)Reverse steps to put back in place.

38

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove

Page 38
Image 38
Regency U39-LP1, U39-NG1 FAN Maintenance, DC Sparker Battery Replacement, To Remove U39 Fan, Alternate Fan Access

U39-LP1, U39-NG1 specifications

The Regency U39-LP1 and U39-NG1 are innovative heating appliances designed for modern homes, emphasizing both efficiency and style. These units encapsulate the essence of contemporary design while ensuring high-performance heating solutions. The U39 series stands out for its user-friendly features and advanced technologies that cater to the demands of varied environments.

One of the main features of the U39-LP1 is its propane-fueled operation, allowing it to generate an impressive amount of heat while remaining energy-efficient. The unit is designed with a remarkable heating capacity, making it ideal for larger spaces or for those chilly evenings where comfort is paramount. In contrast, the U39-NG1 operates on natural gas, appealing to homeowners looking for a more sustainable option. Both models allow for quick and effective heating, ensuring a cozy atmosphere within moments.

The technology embedded in both models reflects a commitment to top-tier performance. The advanced electronic ignition system provides reliability, ensuring seamless operation. The units also incorporate a built-in thermostat, which allows for precise control over the temperature, enhancing comfort while conserving energy. Furthermore, the U39 series features a sleek ceramic glass front that not only adds an aesthetic element but also enhances efficiency by radiating heat effectively into the room.

Another hallmark of the Regency U39 series is its design versatility. Both models are available in various finishes, enabling them to blend seamlessly into different décor styles, whether traditional, modern, or minimalist. The compact dimensions of these units ensure they fit effortlessly into a variety of spaces, from living rooms to basements.

Safety is also a significant focus with the U39-LP1 and U39-NG1. The units come equipped with a variety of safety features, including automatic shut-off and heat-resistant materials, ensuring peace of mind for users.

In summary, the Regency U39-LP1 and U39-NG1 models exemplify modern heating solutions characterized by efficiency, advanced technology, and stylish design. With their user-centric features and commitment to safety, these units are perfect additions for anyone seeking warmth and comfort in their homes. Whether powered by propane or natural gas, the U39 series continues to redefine the standard for home heating.