Regency U39-NG1, U39-LP1 Dura-Ventvertical Terminations, Below Grade Installation, Diagram

Models: U39-LP1 U39-NG1

1 44
Download 44 pages 36.34 Kb
Page 19
Image 19
Below Grade Installation

INSTALLATION

Below Grade Installation

If the Snorkel Termination must be installed below grade, i.e. basement application, proper drainagemustbeprovidedtopreventwaterfrom entering the Snorkel Termination. Refer to Dia.

4.Do not attempt to enclose the Snorkel within the wall, or any other type of enclosure.

Diagram 4

4)If installing the vent termination to a wall with vinyl siding, the Vinyl Siding Standoff must be used. Attach the Vinyl Siding Standoff to the Horizontal VentTermination, but first run a bead of non-hardening mastic around its outsideedges,soastomakeasealbetween vent cap and the standoff. Install the Vinyl Siding Standoff (Part # 950) between the vent cap and the exterior wall and attach with the four wood screws provided. Seal around the Vinyl Siding Standoff on all four sides. Diagram 5. The arrow on the vent cap should be pointing up. Insure that the 1-1/4" clearances to combustible materials are maintained. See diagram 5.

Note:

If installing termination on a siding

 

covered wall, a vinyl siding standoff

 

or furring strips must be used to

 

ensure that the termination is not

 

recessed into the siding. The four

 

wood screws provided should be

 

replaced with appropriate fasteners

 

for stucco, brick, concrete, or other

 

types of sidings.

5)Before connecting the horizontal run of vent pipe to the vent termination, slide the black decorative wall thimble cover over the vent pipe, then slide the Wall Thimble (Part # 942) over the vent pipe.

6)Slide the appliance and vent assembly towards the wall carefully inserting the vent pipe into the vent cap assembly. It is important that the vent pipe extends into the vent cap a sufficient distance so as to result in a minimum pipe overlap of 1-1/4 inches. Secure the connection between the vent pipe and the vent cap by attaching the two sheet metal strips extending from the vent cap assembly into the outer wall of the vent pipe. Use the two sheet metal screws provided to connect the strips to the pipe. Bend any remaining portion of the sheet metal strip back towards the vent cap, so it will be concealed by the decorative wall thimble cover. See diagram 6.

Diagram 6

DURA-VENT VERTICAL

TERMINATIONS

1) Maintain the 1 - 1/4" clearances (air spaces) to combustibleswhenpassing through ceilings, walls, roofs, enclosures, attic rafter, or other nearby combustible surfaces. Do not pack air spaces with insulation. Check the "Rigid Pipe Venting Arrangments" section for themaximumverticalriseof the venting system and the maximum horizontal offset limitations.

2)Set the gas appliance

in its desired location. DURA-VENT VERTICAL Drop a plumb bob down

from the ceiling to the

 

position of the appliance

 

fl ue exit, and mark the

 

location where the vent

 

will penetrate the ceiling.

Diagram 8

Drill a small hole at his point. Next, drop a plumbbobfromtherooftotheholepreviously drilled in the ceiling, and mark the spot where the vent will penetrate the roof. Determine if ceiling joists, roof rafters or other framing will obstruct the venting system. You may wish to relocate the appliance or to offset, as shown in diagram 9 to avoid cutting load bearing members.

Diagram 5

7)Install the Wall Thimble in the center of the 10" square and attach with wood screws.

8)Slide the decorative wall thimble up to the wall surface being careful not to scratch the paintand attach withscrews provided.Apply decorative brass or chrome trim if desired. See diagram 7.

Diagram 9

3)To install the Round Support Box/Wall Thimble in a fl at ceiling, cut a 10 inch square hole in the ceiling centred on the hole drilled in Step 2. Frame the hole as shown in diagram 10.

Diagram 7

Diagram 10

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove

19

Page 19
Image 19
Regency U39-NG1, U39-LP1 installation manual Dura-Ventvertical Terminations, Below Grade Installation, Diagram