TROUBLESHOOTING

Problem

Cause

Excess vibration.

Blade is out of balance.

 

Blade is damaged.

 

Saw is not mounted securely.

 

Work surface is uneven.

 

Blade is warped.

Solution

Replace blade. Replace blade. Tighten all hardware. Reposition on flat surface. Check saw blade installation.

Rip fence does not move smoothly.

Rip fence not mounted correctly.

 

Rails are dirty or sticky.

 

Clamp screw is out of adjustment.

Remount the rip fence. Clean and wax rails. Adjust clamp screw.

Rip fence does not lock at rear.

Clamp screw is out of adjustment.

Adjust clamp screw.

 

 

 

Cutting binds or burns work.

Blade is dull.

Replace or sharpen blade.

 

Blade is heeling.

Align rip fence, miter gauge and/or blade.

 

Work is fed too fast.

Slow the feed rate.

 

Rip fence is misaligned.

Align the rip fence.

 

Riving knife is misaligned.

Adjust the riving knife with shims provided.

 

Separator is out of alignment.

See "To Align Blade Guard Assembly to the

 

 

Blade" in the Assembly section.

 

Wood is warped.

Replace the wood. Always cut with convex

 

 

side to table surface.

 

 

 

Wood edges away from rip fence

Rip fence is misaligned.

Check and adjust the rip fence.

when ripping.

 

 

 

Blade not properly aligned or set.

Resharpen or set blade.