9
ELECTRICAL
WARNING:
To prevent possible electrical hazards, have a
qualified electrician check the line if you are not
certain that it is properly wired.
CHANGING MOTOR VOLTAGE
See Figures 2 - 4.
WARNING:
Electric shock can kill. To reduce the risk of seri-
ous personal injury, never connect plug to power
source until all assembly steps are completed.
NOTE: The table saw is prewired at the factory for 120 V, 60
Hz. Use the following procedures to change motor voltage
from 120 V to 240 V.
Unplug the saw.
Located on the top of the motor is the junction box.
Remove the phillips screw at the back of the junction box
then lift off the cover.
Remove and discard the electrical tape from the wire
connectors. Remove wire connectors.
Reconnect the leads.
Reinstall the wire connectors and wrap each wire with
two layers of new UL listed electrical tape.
Recheck your wiring with the wiring diagrams.
Reinstall the junction box cover using the phillips
screw.
Cut off the 120 volt power cord plug and replace it with
a 3-prong 240 volt, 15 amp. UL listed plug.
Connect the power cord white and black leads,
respectively, to the "hot" plug blade terminals. Connect
the power cord green grounding wire to the plug ground
prong terminal.
Plug your table saw into a 220-240 V, 15 amp., 3-prong
receptacle. Make certain the receptacle is connected to
a 240 V, AC power supply through a 240 V branch circuit
having at least a 15 amp capacity and protected by a
15 amp time-delay fuse or circuit breaker.
Fig. 4
Fig. 2
Fig. 3
FOR USE WITH 220-240 VOLT
GROUNDING
PIN
COVER OF
GROUNDED
OUTLET BOX