r

=SP (Setting coPy) Function: System copy Syntax: stxDM;

stxSP;

Note:

This copies the settings of the card in slot A to the card in slot B.

Phrase Editing

=PC (Phrase Copy) Function: Copy phrase Syntax: stxDM;

stxPC: **** , **** ;

a b

aPhrase number of the copy source

bPhrase number of the copy destination Example) PC:A1,A3;

This copies the contents of phrase “A0001” to phrase “A0003”.

=PD (Phrase Delete)

Function: Delete phrase

Syntax: stxDM;

stxPD: **** ;

a

aPhrase number

=PI (Phrase sIlencer)

Function: Seek and set playback points at the locations of silent portions

Syntax: stxDM;

stxPI: **** ;

a

a Phrase number

Note: Only audio phrases can be specified.

> PT (Phrase Trancate for AR-3000)

Function: Delete audio outside the playback points (Phrase Truncate)

Syntax: stxDM;

stxPT: **** ;

a

a Phrase number

Note: Only audio phrases can be specified.

AR-3000 RS-232C Reference -13

Page 18
Image 18
Roland RS 232C = SP Setting coPy Function System copy Syntax stxDM, = PC Phrase Copy Function Copy phrase Syntax stxDM