Note: When operation is paused with the PE command, the AR-3000 outputs the elapsed time from the start of the phrase to the point where paused.

The number of digits for **F (frame) increases according to the value of MTC type

= AE ( Auto inc rEc start )

Function: Output the total number of phrases recorded on the card

Syntax: stxAE: S**** ; a

a the total number of phrases recorded on the card

Note: This is output when AR receives an AE command.

4.4.2Reply Commands

=ER (ERror)

Function: Replies when an error has occurred.

Syntax: stxER: * ; a

aError number

0Syntax error

This error occurs when correct reception was not possible, such as when the syntax of the command was incorrect or inappropriate.

1The specified phrase does not exist, or the phrase number is incorrect. This error will also be output if a phrase number is specified for a card which is not inserted.

2Busy error.

The AR-3000 is currently recording or playing back. When the AR-3000 is recording or playing back, it will process only the following commands.

 

Control commands

Request commands

During

PA , ST

AC

Recording

 

 

 

 

 

During Play

PA , ST , PE

AC

 

 

 

During Play

PA , ST , PE , RL

AC

Pause

 

 

 

 

 

3An editing command was received when the AR-3000 was not in Delete mode.

4This error occurs if a setting/delete/record command is transmitted while the write protect switch of the card is ON.

5This error occurs when the total number of phrases specified by the PA, PU, or CE commands exceeds the maximum value (100), or when the specified parameter value is outside of the limit of the maximum value.

6This error occurs when the characters being set for a phrase name or card name exceed the maximum value.

7This error occurs when characters other than numerals (0 - 9) are used to specify an integer.

8This error occurs when you attempt to specify a previously recorded phrase as a pattern phrase.

9This error occurs when you attempt to record or copy a phrase on an already

recorded phrase.

10 There is no remaining card capacity.

20 The command could not be executed for some other reason.