Appendix D: Factory Defaults

Upon receiving the Caretaker Plus from the factory, or restoring the unit to default parameters (see 'RESTORE TO DEFAULT FUNCTION'),

The factory default settings are: Timeout: 20 seconds

Protocol Serial: 9600 baud, no parity, 8 bits, 1 stop, DTR flow control

Protocol Parallel: Use busy and acknowledge

Form Feed: Off

Initialization String: None

Unidirectional X-on/X-off: Yes

Parallel Enable Logic: Yes

Reverse Channel Data Timeout: No

Flow Timeout on Busy (Ports 1-8): Yes

Filter Size: O characters

Appendix E: General Specifications

Serial Models

Electrical: RS232 -9 to +9 volts

Protocol: Asynchronous; DTR/DSR, X-on/X-off flow control

Baud Rate: 50-19200 baud

Word Length: 5, 6. 7, or 8

Parity: odd, even, mark, space, or none

Stop bits: 1 or 2

Parallel Models

Electrical: TTL levels

protocol Centronics compatible STBIACWBUSY interface Size and Weight

0.5" wide X 3.5" high X 5.0" deep 5 ports: 7 Ibs 9 ports: 8 Ibs Chassis

Steel tan painted enclosure, rear mounted connectors Aluminum black anodized 5.25" X 19" rack mount (optional) Power

110 volt, 10 VA external wall mount adapter (standard)

220 volt, 10 VA external floor mount adapter (optional)

110 volt, 10 VA external floor mount adapter (optional) Display

Port status LEDS: 1-8

Unit status LEDs: Power, Mode, Data, Busy, Error Environment

0-70 degrees C., 0-95% relative humidity Connectors

Serial: DB25 female

Parallel: Centronics 36 female or DB25 female Warranty

1 year parts and labor. Extended warranty available

34