to indicate entry into configuration mode. Entering configuration mode will stop data transfer to the shared device, and also erase all data in the buffer. No new data can be loaded into the unit while in configuration mode. Press carriage return on your terminal to call the menu. The DATA LED will light indicating entry into the menu mode. You will be prompted for the proper responses.

The configuration menu displays the setup parameters for all ports and allows you to change them. The item to be changed is selected with a single character, followed by a carriage return. You are further prompted to answer questions appropriate for each menu item. Possible responses to each prompt are listed in parentheses. Responses may be entered in either upper or lower case. You may use the backspace key to correct your entry. A carriage return is required to enter the response Entering only a return to a prompt will leave that parameter unchanged except for the initialization string entry, which will clear the string. Replying with a return only to a Y/N (yes/no) prompt will be interpreted as a no. A sample configuration display is shown in TABLE 1.

Table 1. Configuration Menu Display

CARETAKER PLUS CONFIGURATION Rev 3.8 COPYRIGHT 1986-91 ROSE

ELECTRONICS

 

 

 

 

 

 

 

 

Installed memory

64K Front panel switches ..

ENABLED

 

 

 

Timeout

20 Seconds Form teed

.............

DISABLED

 

 

Initialization String.. DISABLED

 

 

 

 

 

 

------

Current protocol -----

 

------ Powerup protocol ------

Port Baud

Parity

Length

Stop

Flow

Baud

Parity Length

Stop Flow

1

9600

NONE

8

1

DTR

9600

NONE

8

1

DTR

2

9600

NONE

8

1

DTR

9600

NONE

8

1

DTR

3

9600

NONE

8

1

DTR

9600

NONE

8

1

DTR

4

9600

NONE

8

1

DTR

9600

NONE

8

1

DTR

P - Change port formal

D - Disable operator switches

T - Change timeout

A - Advanced features

F - Change form feed

K - Keep new configuration

I - Change init. String

X - Exit configuration

Configuration Menu part 1

 

CARETAKER PLUS CONFIGURATION Rev 3.8 COPYRIGHT 1986-91 ROSE ELECTRONICS

-----Advanced Features ------

Unidirectional Xon/Xoff ............. ENABLED Reverse Channel Data Timeout ........ DISABLED Allow Timeout On Busy (Ports 1-8) ... Yes Filter size ......................... 0 Characters

U - Change unidirectlon Xon/Xoff

R - Change reverse channel data timeout A - Change allow timeout on busy

F - Change filter size

X - Return to previous menu

Enter choice (U.R.A,F.X, or H for help) Configuration Menu part 2

8

CARETAKER PLUS INSTALLATION AND OPERATIONS MANUAL

Page 12
Image 12
Rose electronic Automatic Switch manual Electronics, Enabled, Disabled, None DTR